1125100
WPC 1000 User Manual
3-14
Initialization, Setup, and Checkout
Setting the Auto Carry-up Angle
WPC 1000’s Auto Carry-up feature (also called Operator Station Mute) enables the press to
complete a stroke whenever the operator releases the Run/Inch palm buttons after the ram has
passed the Auto Carry-up Angle.
The Auto Carry-up Angle is factory-set to 149° if your WPC 1000 has light curtain firmware,
to 170° if you have non-light curtain firmware. If you change the auto carry-up default
setting, you must use an angle value that is at or past the crankshaft angle at which the pinch
point openings on the press have closed to less than 1/4 in. (6 mm). Pinch points that are less
than 1/4 in. (6 mm) are considered non-hazardous to the operator.
With large presses where the stroke is long and press speed is slow, you must ensure that the
operator cannot release the buttons and reach the pinch point before it closes. This applies
only when Two-hand Control is used to safeguard the point of operation (without light
curtain) and only if any opening allowing access to the pinch point is 1/4 in. (6 mm) or larger.
Set the Auto Carry-up Angle at the correct value to protect the operator. To do so, perform
the following steps:
1.
Set option switch 7 on switch block S101 on the WPC 1000 Control board to OFF to
enable changes to the Auto Carry-up Angle (see Switch 7 – Disabling Access to Stop-time
Limit and Auto Carry-up Angle Settings, page 3-31).
2.
Power down, then power up the WPC 1000 to enable this settings change.
INCORRECT AUTO CARRY-UP ANGLE
• Ensure that the Auto Carry-up Angle is correct. If the operator can reach the pinch point, the
Auto Carry-up Angle must be set so that any hazardous openings are smaller than 1/4 in. by the
time the crankshaft reaches the Auto Carry-up Angle.
• Determine the Auto Carry-up Angle for each tool, based on the crank angle at which the tool’s
hazardous openings are smaller than 1/4 in.
• Change the Auto Carry-up Angle to the correct value when you change tools.
Failure to comply with these instructions will result in death or serious injury.
ELECTRIC SHOCK HAZARD WHEN WORKING INSIDE THE ENCLOSURE
Turn off and disconnect power from WPC 1000 clutch/brake control, the press and any other
machinery it is connected to before working inside the enclosure. This includes power to the press
motor.
Failure to comply with these instructions could result in death or serious injury.
The following Auto Carry-up function also applies to Foot Control. For more information about
using Foot Control for Single Stroke mode, see Single-stroke, Foot Operation, page 4-14 and
Enabling Foot Control in a Foot Switch, page 3-28.
DANGER
!
WARNING
!
NOTICE
Содержание WPC 1000
Страница 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Страница 69: ...1125100 WPC 1000 User Manual 2 42 Installation Figure 2 22 One hand Control Switch Mounting Dimensions ...
Страница 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Страница 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Страница 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......
Страница 229: ......
Страница 230: ......
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......