1.
Set the Stroke Select switch to “SINGLE” and the Mode Select switch to “FOOT.” Verify
that the “Single-stroke select” and “Foot select” LEDs on the WPC 1000 Control board
are lit.
2.
Make sure that option switch 3 on the WPC 1000 Control board is set to OFF, its default
setting (see Enabling Foot Control in a Foot Switch, page 3-28).
3.
Power down, then power back up the WPC 1000, if necessary, to enable the settings
change. The WPC 1000 is now in Foot Trip mode, the press stroking each time the Foot
Switch is depressed.
4.
Depress the Foot Switch and immediately release it. The press should make a single
stroke and stop at top dead center. Verify that the “Foot switch input N/C” LED turns off
when the Foot Switch is depressed and that the “Foot switch input N/O” LED illuminates.
5.
Set option switch 3 to ON.
6.
Power down, then power back up WPC 1000 to enable the settings change. You are now
in Foot Control mode. The press should cycle to Top-stop only if the Foot Switch is held
down past the Auto Carry-up Angle.
7.
Press and hold the Foot Switch through the Auto Carry-up Angle, then release the Foot
Switch. The press should complete the stroke, stopping at Top-stop.
8.
Press and hold the Foot Switch again, but release it before the Auto Carry-up Angle. The
press should begin to cycle but stop immediately when the Foot Switch is released.
9.
Press and hold both Run/Inch buttons. The press should complete the stroke, stopping at
Top-stop.
10.
Set the Stroke Select switch to “CONT.”
11.
Press the Prior Act button on the Operator Station, and, before the indicator lamp goes out,
depress and hold down the Foot Switch. The press should run as long as the Foot Switch
is depressed.
12.
Release the Foot Switch. The press should complete the stroke, stopping at Top-stop.
13.
Depress the Foot Switch and immediately release it. The press should stop after a single
stroke.
Depress the Foot Switch quickly and fully to initiate a stroke. If you depress the Foot
Switch slowly or partially, the press will not stroke.
If the Interrupted Stroke LED flashes, you must depress and hold the Run/Inch buttons on
the Operator Station to bring the press back to top dead center and clear the Interrupted
Stroke before you can operate the Foot Switch.
NOTICE
NOTICE
Содержание WPC 1000
Страница 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Страница 69: ...1125100 WPC 1000 User Manual 2 42 Installation Figure 2 22 One hand Control Switch Mounting Dimensions ...
Страница 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Страница 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Страница 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......
Страница 229: ......
Страница 230: ......
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......