1125100
WPC 1000 User Manual
3-34
Initialization, Setup, and Checkout
The current Cam 1 “on” angle is shown in the LED display and represented at one end of
an illuminated arc of LEDs on the crank-angle clock, as shown in Figure 3-12.
5.
To change the current setting, turn the WPC Settings key switch to “+” (counterclockwise)
to increase the angle or to “–” (clockwise) to decrease the angle.
As you increase or decrease the angle, additional LEDs at one end of the illuminated LED
arc on the crank-angle clock are lit, or currently illuminated LEDs are turned off.
6.
Press the Reset/Select button to illuminate the “Auto Carry-up” segment, which is used to
set the Cam 1 “off” angle when the cam adjustment feature is enabled (see Figure 3-13).
7.
Repeat step 5. The length of the illuminated arc of LEDs on the crank-angle clock
changes as you increase or decrease the Cam 1 OFF angle. Figure 3-13 shows an LED arc
for cam channel 1 settings of ON = 180° and OFF = 205°.
8.
Repeat steps 4 through 7 for the Cam 2 “on” and “off” settings if necessary.
9.
Set option switch 6 back to the OFF position.
10.
Power down WPC 1000, then power it back up to enable the new setting. If you do not
cycle power, the previous switch 6 setting may remain in effect.
Figure 3-13. WPC 1000 Displays Showing Cam Channel 1 OFF Setting (Cam 1 ON = 180°)
If you do not cycle power to the WPC 1000 after moving option switch 6 back to its default
setting, WPC 1000 will remain in cam-setting mode, and you will not be able to adjust the
settings controlled by the indicator segments in the lower half of the display.
WPC 1000 Standard Display
WPC 1000 Optional
Counter Display
INTERRUPTED STROKE
BRAKE WARNING
TOP STOP ANGLE
AUTO CARRYUP
ANGLE / SPM
90
°
STOP TEST
STOP TIME LIMIT
MICRO-INCH
STOPPING TIME
STOPPING ANGLE
BRAKE WARNING
INTERRUPTED STROKE
TOP STOP ANGLE
AUTO CARRYUP
STOP TIME LIMIT
MICRO-INCH
STOPPING TIME
STOPPING ANGLE
90
°
STOP TEST
COUNTER
COUNTER PRESET
ANGLE / SPM
CAM 1
off
on
CAM 2
off
on
To set the OFF angle for cam channel 1,
press the Reset/Select button until
the Auto Carryup segment is lit,
then turn the WPC Settings key
switch to + to increase the
displayed value, or turn the
key to - to decrease
the displayed value.
Cam 1 ON angle = 180°
Cam 1 OFF angle = 205°
NOTICE
Содержание WPC 1000
Страница 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Страница 69: ...1125100 WPC 1000 User Manual 2 42 Installation Figure 2 22 One hand Control Switch Mounting Dimensions ...
Страница 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Страница 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Страница 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......
Страница 229: ......
Страница 230: ......
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......