1125100
WPC 1000 User Manual
2-32
Installation
6.
Locate the master/slave jumper on the Control board of the “slave” unit(s). Move each of
these jumpers to the pins designating “slave.” Refer to the applicable user manual.
7.
Repeat steps 5 and 6 to connect additional “slave” units.
Connecting Other Wintriss Products to WPC 1000
You can connect other Wintriss products to WPC 1000, such as DiPro 1500 and ProCam
1500. Before you wire, complete all WPC 1000 installation, initialization and checkout
procedures. Then run the press in all modes of operation–Inch, Single-stroke, and Continuous
(if applicable). Also make sure that the press has working Top-stop and Emergency-stop
circuits. Verify that the press operates and stops properly before connecting WPC 1000 to
other units. WPC’s operation is extremely important because it will be tied in to the press stop
circuits. Do not forget to mark on your electrical prints where you wire in WPC 1000.
When the Stopping Time is critical to your operation, as it is with die protection, be sure to
wire as follows. Whenever you have Emergency-stop circuits, wire them between terminals
#25and #26 on the Control board. For Top-stop circuits, wire them between terminals #37
and #38. Refer to Figure 1 at the end of the manual for specific wiring schematics.
Use customized status code wiring (see Wiring WPC 1000 User Inputs, page 2-28) when the
auxiliary equipment that you are connecting does not have its own self-explanatory displays,
as are available in DiPro 1500 or AutoSet load analyzers.
Wiring Micro-inch
Micro-inch is a feature that enables you to control the amount of time (and, therefore, the
distance) that the ram moves when the Run/Inch palm buttons are depressed in Inch mode.
Allowing finer adjustments than are possible in Inch, Micro-inch is designed to facilitate setup
on high-speed or short-stroke presses.
Micro-inch can be wired to be permanently enabled or to be switched on and off.
To wire Micro-inch so that it is permanently enabled, install a jumper between pins #157 and
#155 (Ground) on TB705 on the WPC 1000 Display board (see Figure 2-16, page 2-33 and
Table 2-20, page 2-71).
To wire Micro-inch so that it can be turned on and off, wire a switch to pins #157 and #155 on
TB705 as shown in Table 2-7, page 2-33 and Figure 4 at the end of the manual. An optional
Micro-inch On/Off switch is available from Wintriss.
Содержание WPC 1000
Страница 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Страница 69: ...1125100 WPC 1000 User Manual 2 42 Installation Figure 2 22 One hand Control Switch Mounting Dimensions ...
Страница 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Страница 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Страница 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......
Страница 229: ......
Страница 230: ......
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......