3.4
If fuel continues to flow from the screw-in union (003), do as follows (an HP fuel
pipe (001) is defective):
3.4.1
Stop the engine.
3.4.2
Remove each of the three HP fuel pipes (001) until you find the defective
HP fuel pipe (refer to the Maintenance Manual 8733-1).
3.4.3
Do a check for damage on the sealing face of the defective HP fuel pipe
(001). If you find damage, grind the sealing face (refer to the
Maintenance Manual 8733-1).
3.4.4
If the HP fuel pipe is defective, cut out the injection of the related cylinder
and replace the defective HP fuel pipe, refer to the Maintenance Manual.
3.4.5
Tighten the screw-in union (003).
3.4.6
Start the engine.
3.5
If no fuel flows from the screw-in union (003), tighten the screw-in union (003).
4
If there is no fuel flow from none of the leakage pipes (004), find (if applicable) the
connecting pipe that has a leakage as follows:
4.1
On the fuel leakage pipe (003,
), carefully loosen the screw-in union
(005) a maximum of two turns.
4.2
Do a check for fuel flow.
4.3
If there is no fuel flow, tighten the screw-in union (005) and continue with
4.4
If there is fuel flow, tighten the screw-in union (005) and find the connecting pipe
that has a leakage as follows:
4.4.1
Close fully the two valves (008 and 009) of the connecting pipe (006).
4.4.2
On the fuel leakage pipes (003 and 010), carefully loosen the screw-in
unions (002 and 011) a maximum of two turns.
4.4.3
Do a check for fuel flow.
4.4.4
If after a short period no more fuel flows, the connecting pipe (006) is
defective. Replace the connecting pipe (006) as quickly as possible
(refer to the Maintenance Manual, Group 8).
4.4.5
Tighten the screw-in unions (002 and 011).
4.4.6
Open fully the two valves (008 and 009).
4.4.7
again for the connecting pipe (007) with the
valves (001) and (012).
X92DF
AA00-0000-00AAA-311D-A
Operation Manual
Examine the ICU or fuel pipes for fuel leakage
Winterthur Gas & Diesel Ltd.
- 544 -
Issue 002 2020-08
Содержание X92DF
Страница 18: ...X92DF Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 18 Issue 002 2020 08...
Страница 147: ...X92DF Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 147 Issue 002 2020 08...
Страница 253: ...X92DF Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 253 Issue 002 2020 08...
Страница 425: ...7 Installation 7 1 Installation 426 X92DF Operation Manual Winterthur Gas Diesel Ltd 425 Issue 002 2020 08...