5.6.3
Auxiliary blower
The two auxiliary blowers supply air from the air space into the receiver space during the engine
start and during operation at low load. Flaps prevent airflow back from the receiver space to the
air space during usual operation of the turbochargers and during engine stop.
The electric motor (004,
) operates the blower (003).
The auxiliary blowers are installed on the scavenge air receiver, refer to section
.
Fig 5-44
Auxiliary blower (generic)
001
002
004
003
Legend
001
Air outlet
003
Blower
002
Air inlet
004
Electric motor
During the engine start procedure, the first auxiliary blower starts immediately. After
approximately two to three seconds, the other auxiliary blower starts.
If one of the auxiliary blowers becomes defective, you also can start and operate the engine. At
less than full load, there will be more exhaust smoke.
If the two auxiliary blowers become defective, you cannot start the engine.
When the turbochargers give sufficient pressure in the scavenge air receiver, the auxiliary
blowers stop.
If the scavenge air pressure decreases below the minimum pressure necessary, the auxiliary
blowers operate as given above.
The auxiliary blower switch box (refer to section
5.6.4 Auxiliary blower switch box
gives data about the condition of the auxiliary blowers.
X92DF
AA00-6545-00AAA-043A-A
Operation Manual
Auxiliary blower
Winterthur Gas & Diesel Ltd.
- 226 -
Issue 002 2020-08
Содержание X92DF
Страница 18: ...X92DF Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 18 Issue 002 2020 08...
Страница 147: ...X92DF Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 147 Issue 002 2020 08...
Страница 253: ...X92DF Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 253 Issue 002 2020 08...
Страница 425: ...7 Installation 7 1 Installation 426 X92DF Operation Manual Winterthur Gas Diesel Ltd 425 Issue 002 2020 08...