10.2.6
Malfunctions of the exhaust gas system (XX37NN)
Tab 10-37 Exhaust gas temperature downstream of a cylinder is too high
Indication
Possible cause
Procedure
TE3701-nnA
The scavenge air flow is too low
•
Clean the turbocharger.
•
Clean the air flaps in the scavenge air re-
ceiver.
•
Clean the scavenge ports.
This is a result of the malfunction
in
water temperature downstream of
a cylinder is too high
•
Do the repair shown there.
There is air in the cooling water
system
•
Open the vent valves of the cooling water
system.
An injection nozzle is defective
•
Repair or replace the defective injection
nozzle.
The injection time is too long
•
Find the cause and repair the fault.
There are leaks in the cooling wa-
ter system (for example cracks in
a cylinder liner)
•
Find the cause and repair the fault.
There is a fire in the piston under-
side
•
Tab 10-38 Exhaust gas temperature difference downstream of all cylinders is too high
Indication
Possible cause
Procedure
TE3701-nnA
An injection nozzle is defective
•
Repair or replace the defective injection
nozzle.
The fuel supply system is defec-
tive
•
Find the cause and repair the fault.
An exhaust valve is defective
•
Repair or replace the defective exhaust
valve.
Tab 10-39 Exhaust gas temperature upstream of a turbocharger is too high
Indication
Possible cause
Procedure
TE3721-nnA
This is a result of the malfunction
in
Table 10-37 - Exhaust gas tem-
perature downstream of a cylinder
is too high
•
Do the repair shown there.
X92DF
AA00-0000-00AAA-410C-A
Operation Manual
Malfunctions of systems and components
Winterthur Gas & Diesel Ltd.
- 524 -
Issue 002 2020-08
Содержание X92DF
Страница 18: ...X92DF Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 18 Issue 002 2020 08...
Страница 147: ...X92DF Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 147 Issue 002 2020 08...
Страница 253: ...X92DF Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 253 Issue 002 2020 08...
Страница 425: ...7 Installation 7 1 Installation 426 X92DF Operation Manual Winterthur Gas Diesel Ltd 425 Issue 002 2020 08...