![WinGD X92DF Скачать руководство пользователя страница 516](http://html1.mh-extra.com/html/wingd/x92df/x92df_operation-manual_986583516.webp)
Tab 10-5
Supply temperature of the cooling water to the SAC is too low
Indication
Possible cause
Procedure
TE1371A
The cooling water supply system
is defective
•
Find the cause and repair the fault.
Tab 10-6
Temperature of the cooling water downstream of the SAC is too high
Indication
Possible cause
Procedure
TE1381-nnA
This is a result of the malfunction
in
Table 10-4 - Supply pressure of
the cooling water to the SAC is
too low
•
Do the repair shown there.
This is a result of the malfunction
in
ture of the cooling water to the
SAC is too low
•
Do the repair shown there.
X92DF
AA00-0000-00AAA-410C-A
Operation Manual
Malfunctions of systems and components
Winterthur Gas & Diesel Ltd.
- 516 -
Issue 002 2020-08