1
Stop the engine.
2
Loosen the screws of the flange (008,
), but do not loosen one of the two
middle screws.
3
Turn the flange (008) to close the exhaust waste gate.
4
Tighten the screws to attach the flange (008).
5
Start the engine.
CLOSE UP
•
None
X92DF
AA00-8135-00AAA-662A-A
Operation Manual
Temporary isolate the exhaust waste gate
Winterthur Gas & Diesel Ltd.