4.14.4
LDU-20 pages
The LDU-20 panel has the pages that follow (examples).
Fig 4-21
LDU-20 page - LP SCR SYSTEM STATUS (MAIN PAGE)
010
008
009
001
002
003
007
006
005
004
Tab 4-1
LP SCR SYSTEM STATUS (MAIN PAGE)
Item
Function
Effect
001
OVERVIEW button
Opens the SCR system overview page
002
INTERFACES button
Opens the interfaces page
003
INDEX button
Opens the index page
004
SCREENSHOT button
Makes a screenshot of the current screen
005
RCS CTRL OFF button
Gets control from the remote control system (if button is ac-
tive)
006
Status indication
Shows the SCR status
007
Status indication
Shows the control location
008
Status indication
Shows the related status
009
Button and indication
Starts and indicates the related SCR operation mode
010
Status indication
Shows the status of the SCR system
X92DF
AA00-9270-00AAA-043B-A
Operation Manual
LP Selective catalytic reduction system
Winterthur Gas & Diesel Ltd.
- 115 -