![WinGD X92DF Скачать руководство пользователя страница 555](http://html1.mh-extra.com/html/wingd/x92df/x92df_operation-manual_986583555.webp)
PROCEDURE
Fig 10-6
Fuel pump (example) - isolate
1
Release the pressure and drain the related HP fuel pipe (001,
2
Remove the related HP fuel pipe (001) from the fuel pump (002). For the applicable
procedure, refer to the Maintenance Manual.
3
Install the flange (005) to the fuel pump (002).
4
Install the flange (006) to the HP fuel pipe (007).
5
Remove the related cover from the supply unit (003).
6
Remove the related plug (004) from the supply unit (003).
Fig 10-7
Fuel pump (example) - cut out
007
002
X
006
001
003
004
005
00546
X92DF
AA00-5556-00AAA-510B-A
Operation Manual
Disconnect the fuel pump
Winterthur Gas & Diesel Ltd.
- 555 -
Issue 002 2020-08