2.6
Prevent explosions in the crankcase
Periodicity
Description
Unscheduled
Duration for performing preliminary requirements
0.0 man-hours
Duration for performing the procedure
1.0 man-hours
Duration for performing the requirements after job completion
0.0 man-hours
Personnel
Description
Specialization
QTY
Engine crew
Basic
1
Support equipment
Description
Part No.
CSN
QTY
None
Supplies
Description
QTY
None
Spare Parts
Description
Part No.
CSN
QTY
None
SAFETY PRECAUTIONS
WARNING
Danger: If an oil mist alarm is activated, keep away from the engine. There is a risk of
explosion.
WARNING
Danger: Do not open the crankcase doors or the covers for a minimum of 20 minutes
after engine stop. If air goes into the crankcase, an explosion can occur.
WARNING
Injury hazard: The crankcase doors have relief valves. To prevent accidents no person
must be in the areas of gases that can come out of these relief valves. Injury to personnel
can occur.
PRELIMINARY OPERATIONS
•
None
X92DF
AA00-0000-00AAA-012D-A
Operation Manual
Prevent explosions in the crankcase
Winterthur Gas & Diesel Ltd.
- 56 -
Issue 002 2020-08
Содержание X92DF
Страница 18: ...X92DF Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 18 Issue 002 2020 08...
Страница 147: ...X92DF Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 147 Issue 002 2020 08...
Страница 253: ...X92DF Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 253 Issue 002 2020 08...
Страница 425: ...7 Installation 7 1 Installation 426 X92DF Operation Manual Winterthur Gas Diesel Ltd 425 Issue 002 2020 08...