Fig 10-4
Leakage on connecting pipes (generic)
001
002
003
004
005
007
008
006
009
010
011 012
Legend
001
Valve
007
Connecting pipe
002
Screw-in union
008
Valve
003
Leakage pipe
009
Valve
004
Fuel rail
010
Leakage pipe
005
Screw-in union
011
Screw-in union
006
Connecting pipe
012
Valve
5
If none of the connecting pipes have a leakage, find the ICU that has a fuel flow more
than usual (compared to the amount of leakage from the other ICU) as follows:
5.1
Put an oil tray under the screw-in union (008,
) of the fuel leakage
pipe (007) to collect the usual fuel flow.
5.2
Carefully loosen the screw-in union (008) a maximum of two turns.
5.3
Do a check of the fuel flow.
5.4
If fuel flows from the screw-in union (008) more than usual (compared to the
amount of leakage from the other ICU), the fuel quantity piston is defective.
Replace the defective fuel quantity piston (refer to the Maintenance Manual
5564
‑
1).
5.5
Tighten the screw-in union (008).
5.6
again for the other related cylinders.
CLOSE UP
•
None
X92DF
AA00-0000-00AAA-311D-A
Operation Manual
Examine the ICU or fuel pipes for fuel leakage
Winterthur Gas & Diesel Ltd.
- 545 -
Issue 002 2020-08
Содержание X92DF
Страница 18: ...X92DF Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 18 Issue 002 2020 08...
Страница 147: ...X92DF Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 147 Issue 002 2020 08...
Страница 253: ...X92DF Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 253 Issue 002 2020 08...
Страница 425: ...7 Installation 7 1 Installation 426 X92DF Operation Manual Winterthur Gas Diesel Ltd 425 Issue 002 2020 08...