Appendix A
SCPI Command Reference
CALCulate Subsystem
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
717
:CALCulate:EGPRs:RFTX:LENGth:LIMit:STATe
:CALCulate:EGPRs:RFTX:LENGth:LIMit:UPPer[:DATA]
:CALCulate:EGPRs:RFTX:LENGth:LIMit:LOWer[:DATA]
Description
There is solely a query form of this command available.
Query
This command delivers one boolean number, indicating whether the user-definable
limits of the burst length measurement were violated by a measurement result value
or not.
A
0
means that all measurement result values were within the limits set, while a
1
indicates that at least one measurement result value did violate at least one of the
limits. The limits can be set using the commands described below.
Example
:MEAS:EGPR:ARR:RFTX:LENG 10
:CALC:EGPR:RFTX:LENG:LIM?
String returned in this example:
"0"
This string indicates that there was no violation of the measurement limits.
Syntax
:CALCulate:EGPRs:RFTX:LENGth:LIMit:STATe <PredefExp>
Parameters
PredefExp
is one of the following predefined expressions:
ON|OFF
. Default is
ON
.
Description
This command switches the check of the measurement result values of the
MEAS:EGPRs:RFTX:LENGth
measurement against their user-definable limits
either on or off.
Query
There is no query form of this command available.
Example
:CALC:EGPR:RFTX:LENG:LIM:STAT ON
Switches the limit check on frequency measurements on.
Syntax
:CALCulate:EGPRs:RFTX:LENGth:LIMit:UPPer[:DATA] <real1>
Parameters
real1
is a floating point real number. The minimum value for each is
0
, the maxi-
mum is
700
. The resolution is
0.1
and the default value is
562.8
.
Description
Sets the upper limit for the burst length measurement; the physical dimension of the
number stated is microseconds.
Query
There is only a command form available.
Example
:CALC:EGPR:RFTX:LENG:LIM:UPP 563
This command will sets the upper limit of the burst length to 563 μs.
Syntax
:CALCulate:EGPRs:RFTX:LENGth:LIMit:LOWer[:DATA] <real1>
Parameters
real1
is a floating point real number. The minimum value for each is
0
, the maxi-
mum is
700
. The resolution is
0.1
and the default value is
542.8
.
Содержание 4400 Mobile Phone Tester Series
Страница 2: ......
Страница 4: ...ii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 16: ...Table of Contents xiv 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 24: ...Safety Notes Shutdown when defective xxii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 64: ...Chapter 1 Overview Accessories and options 40 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 272: ...Chapter 6 Tools Audio measurements 248 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...