Appendix A
SCPI Command Reference
CALCulate Subsystem
704
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
:CALCulate:EGPRs:RFSPectrum:ACPM:TRANsient:LIMit
:LOWer[:DATA]
:CALCulate:EGPRs:RFSPectrum:MSPectrum:VALue
Syntax
:CALCulate:EGPRs:RFSPectrum:ACPM:TRAN-
sient:LIMit:LOWer[:DATA]
<real1>,<real2>,<real3>,<real4>,
<real5>,<real6>,<real7>,<real8>,
<real9>,<real10>,<real11>,<real12>,
<real13>,<real14>,<real15>,<real16>,
<real17>,<real18>,<real19>,<real20>,
<real21>,<real22>,<real23>,<real24>,
<real25>,<real26>,<real27>
Parameters
realx
are 27 floating point real numbers.
The minimum value for all
realx
is
-100.0
, the maximum value
10.0
. The mini-
mum resolution possible for all
realx
is
0.01
. The default value for all
realx
is
0.0
.
Description
Sets the
lower
limits for the 27 single measurement result values of the ACPM mea-
surement of the spectrum due to switching transients. The physical dimension of the
single data values is dBm.
Query
There is no query form of this command available.
Example
:CALC:EGPR:RFSP:ACPM:TRAN:LIM:LOW?
This command will return the 27 lower limit values.
Syntax
:CALCulate:EGPRs:RFSPectrum:MSPectrum:VALue <real1>
Parameters
real1
is a floating point real number. The minimum value is
-1,000,000.0
, the
maximum is
1,000,000.0
. The minimum resolution possible is
0.1
, the default
value is
-200.0
.
Description
There is only a query form of this command available.
Query
The query form of this command delivers an (interpolated) measurement result value
of the modulation spectrum curve at the frequency specified with the real1 parame-
ter. real1 is interpreted as an offset from the carrier (i.e. the transmission frequency).
The string returned will contain one floating point real number. The physical dimen-
sion of the measurement result value returned is dBc.
Notes:
–
Please note that you need to have a spectrum measurement taken before this
command will return any meaningful result. We recommend to use the
:MEAS:BLOC:MSP:AVG
command to do so.
–
The
:CALC:EGPRs:RFSP:MSP:VAL
command is not really a measurement -
it is an interpolation of the spectrum curve for the frequency specified.
Example
:MEAS:EGPR:BLOC:MSP:AVG 20
:CALC:EGPR:RFSP:MSP:VAL? -50000
This command will interpolate a modulation spectrum measurement at an offset of
50 kHz to the carrier. The value returned in this example is: "
-4.7
".
Содержание 4400 Mobile Phone Tester Series
Страница 2: ......
Страница 4: ...ii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 16: ...Table of Contents xiv 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 24: ...Safety Notes Shutdown when defective xxii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 64: ...Chapter 1 Overview Accessories and options 40 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 272: ...Chapter 6 Tools Audio measurements 248 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...