Appendix A
SCPI Command Reference
CONFigure subsystem
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
425
:CONFigure[:GSM]:MEASure:GROUp[:RFTX]
:CONFigure[:GSM]:MEASure:GROUp:AFANalyser
Syntax
:CONFigure[:GSM]:MEASure:GROUp[:RFTX] <PredefExp1>
,[PredefExp2],[PredefExp3],[PredefExp4]
,[PredefExp5],[PredefExp6],[PredefExp7]
,[PredefExp8],[PredefExp9]
Parameters
PredefExpx
is one of the following predefined expressions:
PPEAk|PRMS|FREQuency|LENGth|UTIMe|POWer|
TEMPlate|CORNer|FLATness
.
Default is
PPEAK
.
Description
This command allows to set a user-specific sequence of RF TX tests on the Willtek
4400. The sequence has to be started with the appropriate commands of the
MEASure
subsystem (
:MEAS:GSM:CONT:RFTX:GROU
or
:MEAS:GSM:ARR:RFTX:GROU
).
The meaning of the parameters is as follows:
PPEAk
is the peak phase error measurement,
PRMS
the root-mean square value of the phase error measurement.
FREQuency
means the frequency error of the mobile under test,
LENGth
the length of the burst in microseconds.
UTIMe
stands for the timing error of the mobile under test in microseconds, taking
the ordered timing advance into account.
POWer
is the mobile's RF output power level in dBm.
TEMPlate
indicates whether the power/time template has been violated by a burst
or not.
CORNER
gives the RF power level in dBm at eight predefined positions of a burst (see
section Corner Points for details).
FLATness
gives an indication whether the mobile's RF output power is constant
during the useful part of the burst.
Notes
–
This command must be used with at least one parameter specified. All other
parameters are optional.
–
Unless organized in this sequence, the start of a new RF TX test will always termi-
nate the preceding one instantly. Therefore, this command is an efficient way to
perform several RF TX measurements in a sequence.
Query
The query form of this command will return the current sequence of RF TX tests to be
performed by the Willtek 4400. The string delivered back will contain a maximum of
nine short-form versions of the predefined expressions explained above.
Example
:CONFigure:GSM:MEASure:GROUp:RFTX PRMS,POWer,FLATness
:CONF:GSM:MEAS:GROU?
Value returned:
"PRMS,POW,FLAT"
Syntax
:CONFigure[:GSM]:MEASure:GROUp:AFANalyser
<PredefExp1>,[PredefExp2],[PredefExp3]
,[PredefExp4],[PredefExp5],[PredefExp6]
Parameters
PredefExpx
is one of the following predefined expressions:
SINad|DISTor-
tion|FREQuency|ACVPeakp|
ACVRms|DCVRms
.
Default is
SINad
.
Содержание 4400 Mobile Phone Tester Series
Страница 2: ......
Страница 4: ...ii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 16: ...Table of Contents xiv 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 24: ...Safety Notes Shutdown when defective xxii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 64: ...Chapter 1 Overview Accessories and options 40 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 272: ...Chapter 6 Tools Audio measurements 248 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...