Appendix A
SCPI Command Reference
CONFigure subsystem
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
435
:CONFigure:EGPRs:BS:ATTach
:CONFigure:EGPRs:BS:MSTAtion:MSLot
:CONFigure:EGPRs:BS:BCC
Example
:CONFigure:EGPRs:BS:RLCMac:BSN:INC OFF
:CONF:EGPRs:BS:RLCM:BSN:INC?
Value returned in this example: "
OFF
"
Syntax
:CONFigure:EGPRs:BS:ATTach <PredefExp>
Parameters
PredefExp is one of the following predefined expressions:
ON|OFF
.
Default is
OFF
.
Description
Switches the IMSI Attach/Detach flag in the System Information messages broadcast
on the BCCH on or off. If ON, the mobile must register and deregister with the net-
work simulated by the Willtek 4400 when switched on or off, respectively. This can be
used to detect when the mobile is switched on and listening to the Willtek 4400 net-
work.
Query
The query form of this command will return the current setting. The string delivered
back will contain one of the predefined expressions as explained above.
Example
:CONFigure:EGPRs:BS:ATTach OFF
:CONF:GSM:BS:ATT?
Value returned in this example: "
OFF
".
Syntax
:CONFigure:EGPRs:BS:MSTAtion:MSLot <int1>
Parameters
int1
is an integer parameter.
The minimum value for
int1
is
1
, the maximum value is
4
. The default value for
int1
is
1
.
Description
This command either sets the number of UL time slots expected by the Willtek 4400
(asynchronous mode) or the number of UL time slots that the mobile under test is
commanded to use (synchronous mode) during multislot testing.
Note:
HSCSD or multislot testing requires the Multislot Option to be installed on your
Willtek 4400. More details on multislot testing can be found in section Multislot
Testing.
Query
The query form of this command will return the current setting. The string delivered
back will contain one integer.
Example
:CONFigure:EGPRs:BS:MSTAtion:MSLot 4
:CONF:EGPRs:MSTA:MSL?
Value returned in this example: "
4
".
Syntax
:CONFigure:EGPRs:BS:BCC <int1>
Parameters
int1
is an integer.
The minimum value for
int1
is
0
, the maximum value is
7
. The default value for
int1
is
0
.
Description
This command sets the base station color code.
Содержание 4400 Mobile Phone Tester Series
Страница 2: ......
Страница 4: ...ii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 16: ...Table of Contents xiv 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 24: ...Safety Notes Shutdown when defective xxii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 64: ...Chapter 1 Overview Accessories and options 40 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 272: ...Chapter 6 Tools Audio measurements 248 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...