Appendix A
SCPI Command Reference
MEASure subsystem
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
543
:MEASure:EGPRs:ARRay:RFTX:ERMS
:MEASure:EGPRs:ARRay:RFTX:EPEAk
Example
:MEASure:EGPRs:ARRay:RFTX:ALL 2
:FETCh:EGPRs:RFTX:ALL?
In this case, the sequence of the most important EGPRS RF TX measurements will be
performed twice. All 34 measurement result values will be kept in an internal memory
until they are read out with the
FETCh
command. After the internal memory has
been read out, it will be cleared.
Note:
A subsequent :
FETCh
command (without any previous start of a measure-
ment) will therefore try to read non-existing measurement data and thus create a
timeout error.
Syntax
:MEASure:EGPRs:ARRay:RFTX:ERMS <int1>
Parameters
int1
is an integer.
The minimum value for
int1
is
0
, the maximum value is
100
. The default value for
int1
is
0
.
Description
Measures multiple times (set with the
int1
parameter) the error vector magnitude
rms-averaged over a burst. EVM is a relative value and shown as a percentage. To
read out the entire measurement results array, use the
:FETCh:EGPRs:RFTX:ERMS
command.
Query
The query form of this command returns a string, containing
int1
floating point real
numbers with the physical dimension of %, representing the measurement results.
The single measurement results are separated by commas.
Example
:MEAS:EGPRs:ARR:RFTX:ERMS 5
:FETC:EGPRs:RFTX:ERMS?
The error vector magnitude rms-averaged measurement will be performed five times.
The measurement results will be stored internally and read by the
FETC
command.
An example of the string returned is: "
2.33,2.53,1.97,2.41,1.79
".
Syntax
:MEASure:EGPRs:ARRay:RFTX:EPEAk <int1>
Parameters
int1
is an integer.
The minimum value for
int1
is
0
, the maximum value is
100
. The default value for
int1
is
0
.
Description
Measures multiple times (set with the
int1
parameter) the maximum error vector
magnitude within a burst. EVM is indicated per cent. To read out the entire measure-
ment results array, use the
:FETCh:EGPRs:RFTX:EPEAk
command.
Query
The query form of this command returns a string, containing
int1
floating point real
numbers with the physical dimension of %, representing the measurement results.
The single measurement results are separated by commas.
Example
:MEAS:EGPRs:ARR:RFTX:EPEAk 5
:FETC:EGPRs:RFTX:EPEAk?
The maximum error vector magnitude measurement will be performed five times. The
measurement results will be stored internally and read by the
FETC
command. An
example of the string returned is: "
6.33,8.53,11.97,9.41,10.79
".
Содержание 4400 Mobile Phone Tester Series
Страница 2: ......
Страница 4: ...ii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 16: ...Table of Contents xiv 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 24: ...Safety Notes Shutdown when defective xxii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 64: ...Chapter 1 Overview Accessories and options 40 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 272: ...Chapter 6 Tools Audio measurements 248 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...