Appendix A
SCPI Command Reference
STATus subsystem
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
399
:STATus:OPERation:SIGNalling:EVDO:NTRansition
:STATus:OPERation:MEASuring[:EVENt]?
:STAT:OPERation:MEASuring:CONDition?
Example
:STATus:OPERation:SIGNalling:EVDO:PTRansition 0
This means that none of the positive transitions of the condition-type register will be
forwarded to the event-type register.
Syntax
:STATus:OPERation:SIGNalling:EVDO:NTRansition <int1>
Parameters
int1
is an integer. The minimum value for
int1
is
0
, the maximum value is
32767
. The value default is
0
.
Description
Sets the NTR mask of the signaling operation register group. This mask will be
AND
ed
with the up to 15 bits of the NTR filter of the signaling operation
condition
register
to allow a reset (negative transition) of any bit (i.e. a transition from logic '1' to '0') to
reach the signaling operation
event
register.
Note:
The default of this mask is 0 - that means that the mask will
not
allow any
negative transition of the lower 15 bits of the condition-type register to reach the
event-type register of this group.
Query
There is no query form of this command available.
Example
:STATus:OPERation:SIGNalling:EVDO:NTRansition 0
This means that none of the negative transitions of the condition-type register will be
forwarded to the event-type register.
Syntax
:STATus:OPERation:MEASuring[:EVENt]?
Parameters
There are no parameters.
Description
Reads out the current contents of the measuring operation event register.
Note:
Event-type registers are read-only and self-destructive. They will be cleared
after any query.
Query
There is only a query form of this command available. The query will return a string,
containing one integer. The value returned represents all measuring operation events
that have occurred since the last query of this register. As with any event-type regis-
ter, the single bits will remain set even when the reason for the bits to be set is no
longer valid. Please note that this is the main difference between event-type and
condition-type registers. Condition-type registers reflect the current state of the
Willtek 4400. Consequently, the condition type registers will be updated continu-
ously.
Notes
–
For further details regarding the basic functions of the STATus subsystem, please
refer to section
Understanding the STATus Subsystem
.
–
In case, a certain event shall be trapped in a loop within a program, always query
the event-type register.
Example
:STATus:OPERation:MEASuring:EVENt?
Value returned: "
8
".
This means that bit 3 (stands for AF measurement) has been set.
Syntax
:STAT:OPERation:MEASuring:CONDition?
Содержание 4400 Mobile Phone Tester Series
Страница 2: ......
Страница 4: ...ii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 16: ...Table of Contents xiv 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 24: ...Safety Notes Shutdown when defective xxii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 64: ...Chapter 1 Overview Accessories and options 40 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 272: ...Chapter 6 Tools Audio measurements 248 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...