Appendix A
SCPI Command Reference
CALCulate Subsystem
658
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
:CALC:AFANalyser:ALL:LIMit[:FAIL]?
:CALCulate:AFANalyser:ALL:LIMit:STATe
Query
Returns the
mean value
and the
standard deviation
of the audio measurement
results since the last measurement start. The string delivered back contains as many
pairs of mean and standard deviation values as measurement types performed. The
individual values all have the format of floating point real numbers and will be sepa-
rated by commas.
Example
:CALC:RES
:MEAS:AFAN:ACV
...(other SCPI commands)...
:CALC:AFAN:MSIG?
In this example, first a continuous measurement of the audio voltage is started. After
some time, the
:CALC:AFAN:MSIGma
command is used to read out the mean
voltage and its standard deviation. The string returned in this example is
"1.1,
0.2"
.
Syntax
:CALC:AFANalyser:ALL:LIMit[:FAIL]?
Parameters
There are no parameters.
Description
There is solely a query form of this command available.
Query
This command delivers six boolean numbers in a string, separated by commas. These
numbers indicate whether the six single measurement result values of the
MEAS:AFAN:ALL
measurement did violate their individual limits (set with the
commands explained below) or not.
The position of the boolean number within the string returned indicates the result of
the check of following measurements:
1. the peak-to-peak measurement of the AC voltage,
2. the root-mean square value of the AC voltage,
3. the RMS-valued AC ripple on a DC voltage,
4. the audio frequency measurement,
5. the measurement of the third-harmonic distortion (THD) of a sine wave and
6. the SINAD measurement.
While a
0
on any position indicates that the related measurement result value is
within the limits specified, a
1
indicates that the measurement result value did vio-
late at least one of the limits set for the related test.
Example
:MEAS:AFAN:ALL
:CALC:AFAN:ALL:LIM?
String returned:
"0,0,0,0,1,0"
The
1
on position 5 indicates that the distortion measurement is off its limits.
Syntax
:CALCulate:AFANalyser:ALL:LIMit:STATe <PredefExp>
Parameters
PredefExp
is one of the following predefined expressions:
ON|OFF
. Default is
ON
.
Description
This command switches the check of the measurement result values of the
MEAS:AFAN:ALL
measurement against their user-definable limits either on or off.
Query
There is no query form of this command available.
Example
:CALC:AFAN:ALL:LIM:STAT ON
Switches the limit check of the main audio measurements on.
Содержание 4400 Mobile Phone Tester Series
Страница 2: ......
Страница 4: ...ii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 16: ...Table of Contents xiv 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 24: ...Safety Notes Shutdown when defective xxii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 64: ...Chapter 1 Overview Accessories and options 40 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 272: ...Chapter 6 Tools Audio measurements 248 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...