Appendix A
SCPI Command Reference
FETCh Subsystem
596
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
:FETCh:EGPRs:RFTX:EPEAk?
:FETCh:EGPRs:RFTX:ENFTh?
:FETCh:EGPRs:RFTX:EOFFset?
Example
:MEAS:EGPR:ARR:RFTX:ERMS 5
:FETC:EGPR:RFTX:ERMS?
The error vector magnitude rms-averaged measurement will be performed five times.
The measurement results will be stored internally and read by the FETC command. An
example of the string returned is:
"2.33,2.53,1.97,2.41,1.79"
.
Syntax
:FETCh:EGPRs:RFTX:EPEAk?
Parameters
There are no parameters.
Description
There is solely a query form of this command available.
Query
The query form of this command returns the latest measurement result value(s) of the
MEAS:EGPR[:ARR]:RFTX:EPEA
measurement. The string delivered back will
contain at least one floating point real number with the physical dimension of %.
Example
:MEAS:EGPR:ARR:RFTX:EPEA 5
:FETC:EGPR:RFTX:EPEA?
The maximum error vector magnitude measurement will be performed five times. The
measurement results will be stored internally and read by the FETC command. An
example of the string returned is:
"6.33,8.53,11.97,9.41,10.79"
.
Syntax
:FETCh:EGPRs:RFTX:ENFTh?
Parameters
There are no parameters.
Description
There is solely a query form of this command available.
Query
The query form of this command returns the latest measurement result value(s) of the
MEAS:EGPR[:ARR]:RFTX:ENFT
measurement. The string delivered back will
contain at least one floating point real number with the physical dimension of %.
Example
:MEAS:EGPR:ARR:RFTX:ENFT 5
:FETC:EGPR:RFTX:ENFT?
The maximum error vector magnitude measurement will be performed five times. The
measurement results will be stored internally and read by the FETC command. An
example of the string returned is:
"4.33,5.53,1.97,3.41,2.79"
.
Syntax
:FETCh:EGPRs:RFTX:EOFFset?
Parameters
There are no parameters.
Description
There is solely a query form of this command available.
Query
The query form of this command returns the latest measurement result value(s) of the
MEAS:EGPR[:ARR]:RFTX:EOFF
measurement. The string delivered back will
contain at least one floating point real number with the physical dimension of dBc.
Содержание 4400 Mobile Phone Tester Series
Страница 2: ......
Страница 4: ...ii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 16: ...Table of Contents xiv 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 24: ...Safety Notes Shutdown when defective xxii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 64: ...Chapter 1 Overview Accessories and options 40 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 272: ...Chapter 6 Tools Audio measurements 248 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...