Appendix A
SCPI Command Reference
MEASure subsystem
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
471
:MEASure:GSM[:CONTinuous]
:BLOCkdata:PSCShape[:CURRent]
:MEASure:GSM[:CONTinuous]:RFRX:STOP
Description
Starts a process that measures and averages the modulation spectrum for a specified
number of times. The aim of this measurement is to obtain a 'smoothed' modulation
spectrum curve in order to graphically display the modulation spectrum on another
computer or to perform some special analysis.
Further information regarding this kind of measurement can be found in section
“:MEAS[:CONT]:BLOCkdata” on page 358
.
Note:
To read out the measurement result values of the averaging process, the
:FETCh:GSM:RFTX:BLOCkdata:MSPectrum
command may be used.
Query
The query form of this command will start the averaging process and return an array
of measurement result values as soon as all the measurements have been completed.
The string delivered back will contain a set of floating point real numbers with the
physical dimension of dB.
The number of measurement result values depends on the span and the resolution
currently set for the modulation spectrum analyzer.
The span can be set using the
:RFSP:MSP:SPAN
command; the resolution may
be set using the
:RFSP:MSP:RES
command.
The data array returned will only contain measurement result data values (there are
no offset or reference levels in the first data positions).
The single measurement result values are separated by commas.
Example
:MEAS:GSM:CONT:BLOCkdata:MSPectrum:AVG? 25
The array returned is:
"-61.0,-61.0,-61.1, ...0.0,0.0,0.0,...-
61.0"
.
Syntax
:MEASure[:GSM][:CONTinuous]:BLOCkdata:PSCShape[:CUR-
Rent]
Parameters
There are no parameters.
Description
Starts a continuous measurement of the current shape curve. To read out the mea-
surement result values of the latest curve, use the
:FETCh:BLOCkdata:PSC-
Shape
command.
The aim of this measurement is to obtain the current consumption values at each
point in time during an entire TDMA frame. The time/current points are also drawn
as a curve on the Power Supply graphical display.
Further information regarding this kind of measurement can also be found in section
“:MEAS[:CONT]:BLOCkdata” on page 358
.
Query
The query form of this command will start the measurement and return an array of
measurement result values as soon as the measurement has been completed. The
string delivered back will contain 886 floating point real numbers with the physical
dimension of mA. The current is sampled at a rate of 192 kHz, starting with the
beginning of a new downlink TDMA frame.
Example
:MEAS:GSM:CONT:BLOCkdata:PSCShape?
Returns 886 measurement values, describing the current shape over a TDMA frame.
Syntax
:MEASure:GSM[:CONTinuous]:RFRX:STOP
Parameters
There are no parameters.
Содержание 4400 Mobile Phone Tester Series
Страница 2: ......
Страница 4: ...ii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 16: ...Table of Contents xiv 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...