Chapter 3
GSM Asynchronous Mode Operation
Spectrum measurements
154
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
Setting the center frequency
In asynchronous mode (i.e. when there is no signaling exchange between the
mobile under test and the 4400), the center frequency is identical to the
frequency set on the analyzer frequency entry field of the Analyzer menus.
Peak-hold function
As required in the GSM specifications, the measurements have to be carried out
under peak-hold conditions. Therefore, the 4400 provides a user-selectable
peak-hold function.
This means that the peak measurement result values out of a series of measure-
ments will be searched for and displayed. The number of single measurement
runs already taken into account is shown on the
Count
display field.
Working with the peak-hold function
– Start the peak-hold function by pushing the
|Start Peak|
softkey.
– The 4400 will now start the peak-hold process. This means that the peak
measurement result value for every single (of the 27) measurement frequen-
cies will be displayed on-screen. The number of single measurement runs
taken into account is shown on the
Count
display field.
The softkey will change to
|Stop Peak|
.
Important to note
– A reset of the peak-hold process can be achieved by pushing the
|Reset|
softkey.
– In case the live display is frozen and unfrozen (using the appropriate softkey)
during a peak-hold process, the peak-hold process will not be interrupted
but will continue in the background.
– Even when the live display has been frozen, a reset of the peak-hold process
is possible, pushing the
|Reset|
softkey.
Softkeys
The softkeys of the RF spectrum measurement menus provide access to special
functions and features.
Softkeys of the modulation
spectrum menus
A push on this softkey starts the averaging tool of the spec-
trum analyzer. See description in section
“Modulation spec-
trum measurements”
or
“ACPM modulation spectrum
measurements”
for reference.
When the averaging tool is running, the softkey will change
to
|Stop Avg.|
.
A push on this softkey stops the averaging tool of the spec-
trum analyzer and takes you back to the related modulation
spectrum measurement.
The softkey will change to
|Start Avg.|
.
Содержание 4400 Mobile Phone Tester Series
Страница 2: ......
Страница 4: ...ii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 16: ...Table of Contents xiv 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 24: ...Safety Notes Shutdown when defective xxii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 64: ...Chapter 1 Overview Accessories and options 40 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 272: ...Chapter 6 Tools Audio measurements 248 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...