Appendix A
SCPI Command Reference
FETCh Subsystem
4460 GSM System Option and 4468 EDGE System Option
Version 12.20
593
:FETCh:PSUPply:APOWer
:FETCh:PSUPply:ACURrent
Description
There is solely a query form of this command available.
Query
This query returns the latest measurement result values of the
:MEAS[:ARRay]:PSUP:ALL
measurement in a string. All measurement result
values of the power and current consumption measurements are floating point real
numbers, separated by commas.
The order of the measurement result values within the result string is as follows:
1.
APOW
, representing the average power consumption (in mW),
2.
ACUR
, representing the average current consumption, expressed in mA,
3.
PCUR
, representing the peak current consumption, expressed in mA.
Note:
Any current measurement will need the MS Power Supply and Current Mea-
surement options to be installed on your Willtek 4400.
Example
:MEAS:PSUP:ALL
:FETCh:PSUP:ALL?
Returns a string like "
893.5,395.4,1256.2
".
Syntax
:FETCh:PSUPply:APOWer?
Parameters
There are no parameters.
Description
There is solely a query form of this command available.
Query
This query returns the latest measurement result values of the
:MEAS[:ARRay]:PSUP:APOW
measurement in a string. The measurement result
value is a floating point real numbers representing the average current consumption,
expressed in mA.
Note:
Any current measurement will need the MS Power Supply and Current Mea-
surement options to be installed on your Willtek 4400.
Example
:MEAS:PSUP:APOW
:FETCh:PSUP:APOW?
Returns a string like "
893.5
" giving the average power consumption in mW.
Syntax
:FETCh:PSUPply:ACURrent?
Parameters
There are no parameters.
Description
There is solely a query form of this command available.
Query
This query returns the latest measurement result values of the
:MEAS[:ARRay]:PSUP:ACUR
measurement in a string. The measurement result
value is a floating point real numbers representing the average current consumption,
expressed in mA.
Note:
Any current measurement will need the MS Power Supply and Current Mea-
surement options to be installed on your Willtek 4400.
Example
:MEAS:PSUP:ACUR
:FETCh:PSUP:ACUR?
Returns a string like "
395.4
" giving the average current consumption in mA.
Содержание 4400 Mobile Phone Tester Series
Страница 2: ......
Страница 4: ...ii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 16: ...Table of Contents xiv 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 24: ...Safety Notes Shutdown when defective xxii 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 64: ...Chapter 1 Overview Accessories and options 40 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...
Страница 272: ...Chapter 6 Tools Audio measurements 248 4460 GSM System Option and 4468 EDGE System Option Version 12 20 ...