WF20T
Case Former
Engineering Specifications
10-96
10 ENGINEERING SPECIFICATIONS
10.1
Operating Parameters
Table 31: Operating Parameters
Safety Guarding
Integrated safety guarding with keyed interlock switches.
UL/cUL listed standard electrical control panel, NEMA 12.
Meets NFPA-79 standard.
Built-in 24V DC power supply for safe, low voltage sensors and
operating controls.
Controls
PLC operated sequence and timing control.
Power Requirement
120V AC, 1-phase, 60Hz (other voltages available).
Speed
Approximately 10 Cases Per Minute depending on case size and
quality.
Air Requirement
6 SCFM
Tape System
DEKKA Model WX-22 tape applicator head. Other makes optional.
Approx. Weight
1,800 lbs (820 kg).
Case Styles
RSC (Regular Slotted Case); HSC (Half Slotted Case); other styles
available upon request.
Change-Over Time
Approximately 10 – 15 minutes.
Safety Compliance
Lock-out provision on main electrical and air shutoffs.
Содержание WF-10T
Страница 2: ...WF 10T Case Former ...
Страница 118: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 106 ...
Страница 119: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 107 ...
Страница 120: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 108 ...
Страница 121: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 109 ...
Страница 122: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 110 ...
Страница 123: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 111 ...
Страница 125: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 113 ...
Страница 126: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 114 ...
Страница 127: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 115 ...
Страница 128: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 116 ...
Страница 129: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 117 ...