WF-10T
Case Former
Machine Maintenance
9-81
9.2
General Troubleshooting
The most common error in troubleshooting packaging machinery problems is an incorrect
diagnosis of the problem. Errors cause much lost time and needless expense and are avoided by
a careful analytical approach before attempting corrective action. Always start by ensuring that
all case size adjustments have been made correctly. Refer to Section 7:
Establish whether a problem is mechanical, pneumatic, or electrical in nature.
•
If a pneumatic or air-powered mechanism fails to operate properly, first switch
OFF
the
air and attempt to move the mechanism by hand.
•
If the system moves freely, no mechanical problems are indicated, and the air can be
switched
ON
. Now operate the appropriate solenoid valve manually.
•
If the mechanism moves normally when the valve is actuated manually, then the
pneumatic system is working and the problem is electrical in nature. It may be that the
solenoid coil on the valve has failed, or it may be that there is a problem with the signal
reaching the valve
.
Continue this diagnostic systematic approach until the exact malfunctioning component has been
isolated; corrective action will then usually be obvious
.
The following is a list of some common mechanical problems that can occur, and suggestions for
dealing with them. More advanced troubleshooting may require special training.
WARNING!
Switching OFF the air pressure is very important, as air
cylinders can store energy and cause serious injury if
suddenly released from a jammed condition.
Содержание WF-10T
Страница 2: ...WF 10T Case Former ...
Страница 118: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 106 ...
Страница 119: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 107 ...
Страница 120: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 108 ...
Страница 121: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 109 ...
Страница 122: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 110 ...
Страница 123: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 111 ...
Страница 125: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 113 ...
Страница 126: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 114 ...
Страница 127: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 115 ...
Страница 128: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 116 ...
Страница 129: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 117 ...