Service and Maintenance Procedures
8.2.1 Uni-Drive Side-Belt Drive System
The Uni-Drive side-belt system is designed to keep the case square during sealing, which results
in a technically stronger seal and a better finished appearance.
This is achieved by linking the drives on the side-belts to a single motor and reduction gear that
inherently synchronizes belt speeds. In the Uni-Drive system, both belts are linked by single
continuous loop of machine chain, and are driven via a simple self-compensating serpentine
system running over four sprockets, as shown below.
Figure 8-1: Serpentine Chain Drive
8.2.2 Chain Drive
Chain tension is preset at the factory, but if adjustment is needed, tighten idler sprocket. Proper
tension is achieved when the horizontal sag in the chain measures between 1/8” and ¼”, with the
drivebelts in a fully opened position.
The chain should be lubricated once every one hundred hours of operation using a chain spray
lubricant. If it becomes necessary to access the chain drive, remove the stainless steel safety
covers by unfastening the screws that attach them to the machine frame cross member. The
WF-10T Spare Parts Maintenance Kit contains all of the parts necessary for maintaining the Uni-
Drive system. Contact the factory or your local WEXXAR/BEL distributor for price and availability.
NOTE: Depending on case weight, dimensional variations and
conveyor belt wear, it may be necessary to make minor
adjustments to the conveyor belt settings for best performance.
SAFETY!
The covers must be replaced prior to restarting the
machine.
Содержание WF-10T
Страница 2: ...WF 10T Case Former ...
Страница 118: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 106 ...
Страница 119: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 107 ...
Страница 120: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 108 ...
Страница 121: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 109 ...
Страница 122: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 110 ...
Страница 123: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 111 ...
Страница 125: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 113 ...
Страница 126: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 114 ...
Страница 127: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 115 ...
Страница 128: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 116 ...
Страница 129: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 117 ...