WF-10T
Case Former
Component Identification
1-3
1.4
Lock-out Provision
The WF-10T is lock-out / tag-out compliant on both
the electrical and pneumatic main shut-offs. Both
the main electrical disconnect and the filter-
regulator assembly can be locked out on our
WEXXAR Case Formers. Ensure that you lock out
the machine and adhere strictly to the safety
precautions listed in Section 6.2.1:
prior to performing any repairs or
maintenance.
1.5
Compressed Air
Compressed air is used to power the movement of many machine motions. You must be sure
that the machine's main air solenoid valve is shut off before attempting to clear jams or make
minor adjustments which require you to get close to the moving parts of the machine. This air
valve shuts off when the guard doors are opened, or when the main power is switched off.
To safely carry out service or repair work on the machine, a lockable shutoff valve is located on
all WEXXAR machines upstream of the filter-regulator unit. Padlock this valve in the
OFF
position for absolute safety during service work. Always follow local lock-out/tag-out regulations.
Always exercise caution when switching the compressed air back
ON
. Stay well clear of all
moving parts, as they may move quickly when the pressure is reapplied. Make sure that no other
people are in a dangerous position when switching the compressed air on.
1.6
Electrical Power
The main supply voltage for the WF-10T is 120V 60Hz single-phase. Switch off the main power
disconnect switch located on the control panel, and lock it out before attempting service work
outside of the electrical enclosure. Before performing service work inside of the electrical
enclosure, disconnect all electrical power to the machine (customer supplied disconnect).
1.7
Conveyor Drivebelts
Where used, the optional outfeed conveyor drivebelt systems used on WEXXAR packaging
machines operate at moderate speeds. Be sure to keep fingers well clear of all moving parts, as
the gearmotor develops substantial torque, and does not stop easily. Do not wear loose clothing,
jewelry, or accessories (e.g., neckties) when operating WEXXAR packaging machines.
1.8
Guard Doors and Safety Plating
WEXXAR/BEL takes your safety seriously, offering the added benefit of safety guarding on all of
our WF Series units, which prevent operators from reaching into the machine during routine
operation and maintenance.
Figure 1-1: Locked Out Electrical
Disconnect and Filter-Regulator
Assembly
Содержание WF-10T
Страница 2: ...WF 10T Case Former ...
Страница 118: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 106 ...
Страница 119: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 107 ...
Страница 120: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 108 ...
Страница 121: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 109 ...
Страница 122: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 110 ...
Страница 123: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 111 ...
Страница 125: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 113 ...
Страница 126: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 114 ...
Страница 127: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 115 ...
Страница 128: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 116 ...
Страница 129: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 117 ...