250050 R1
33
3. In addition to wiping down wall sheets, a food-grade oil can also be applied with a clean, lint-free cloth. This
will assist in preventing any further moisture from contacting the galvanizing on the steel. Due to safety
concerns with installation and use, Westeel does not recommend the use of oil on other parts such as roof
sheets and safety ladders.
4.9. Grain Bin Use
• Do not off-center unload a grain bin. It is imperative to unload from the center of the bin first, until as much
grain as possible has been removed, and only then proceed to unload from the next closest unload gate to
the center. Continue utilizing the unload gates in succession from the center towards the outside. Gate
control mechanisms should be clearly marked and interconnected to prevent an external gate from being
opened first.
• The only exception to center unloading is when a properly designed and installed side draw system is
utilized. However, as bins tend to go out of round when employing side draws, the bin must be completely
emptied before refilling.
• When unloading a bin with a mobile auger through a properly designed auger chute, the entry end of the
auger should be pushed into the center of the bin before the auger is engaged. Slower rates of flow are
preferable and should not exceed the capacity of an 8” auger.
• Ensure that the inner door panels of grain bin doors are completely closed and latched before filling the
grain bin.
• Never enter a loaded grain bin for any reason. Grain can be a killer.
4.10. Important Notes
• Westeel does not provide a foundation design for this product, and is not liable for any damages or injuries
related to inadequately designed or constructed foundations. Customers must contract professional services
for all foundation design and construction work.
• In order to maintain your wall sheets in good condition separate sheets and allow air circulation between
them. Store sheets in a dry place. Do not store sheets with sheet ends pointing upwards.
• To keep an even pressure on walls, the bin must always be unloaded from the centre.
• Contact local power officials for minimum power line clearance.
• See
Section 4.7 – Critical Assembly Requirements on page 31
for mandatory siting and assembly
requirements.
• Store only non-corrosive, free-flowing materials up to 55 lbs/ft
3
(880 kg/m
3
) average compacted density in
Westeel bins.
• Tighten all bolts to the recommended torque settings.
• Do not locate grain bins close to high buildings, which might cause snow to fall onto or build up on the roof
of the grain bin. Consider future expansion and allow space for loading and unloading of the bin. Your dealer
and local government agricultural consultants can help you plan your storage system for maximum
efficiency.
EASYDRY® WIDE-CORR CENTURION® GRAIN BIN – GRAIN BIN DRYER