HOISTWAY WIRING
LAYOUT
SERIES :
008 , 114, 021, 022, 115, 116, 118, 210
PTE10035-D
Notes:
•
High voltage and low voltage
must run separate and only cross
over perpendicular to each other.
•
Disconnect power to the elevator
before wiring these components.
•
Be warned of the potential for
personal injury if you are no
careful.
•
Do not route wires across landing
face walls.
•
All wiring must meet N.E.C. and
local codes.
•
Use 18 gauge stranded low
voltage wiring other than
provided harnesses.
•
Refer to proper pages for
individual component
installation.
•
If the unit that you are
working on is equipped
with EMI-
III
’s be sure the
jumper is installed
between DC and DL
in the controller.
CRUSH
HAZARD
CUTTING
HAZARD
CRUSH
HAZARD
CRUSH
HAZARD
CRUSH
HAZARD
CRUSH
HAZARD
ELECTRIC
HAZARD
FALLING
HAZARD
ANTI-
STATIC
ALERT
This illustration is an example of cable layout with the least voltage drop throughout
the circuit.
HALL STATION
INTERLOCK
HALL STATION
INTERLOCK
HALL STATION
INTERLOCK
CONTROLLER
PIT
PIT SWITCH
JUNCTION BOX
JUNCTION BOX
JUNCTION BOX
GAL Interlock
EMI Interlock
Hallstation
Controller Box
Pit Switch