![VTS Medical Systems VTS5000 Series Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/vts-medical-systems/vts5000-series/vts5000-series_operating-instructions-manual_1056181080.webp)
76
ASCII mode is reserved at present
FB.04
Response delay
0~200ms
1ms
5
×
FB.05
Transmission
response
0: response for write operation
1: no response for write operation
1
0
×
FB.06
Ratio correlation
coefficient
0.01~10.00
0.01
1.00
o
FB.07
Communication
mode
0: general mode
1: MD380mode
1
0
×
FC Group – Advanced Function and Performance Parameters
FC.00
Dynamic braking
0: disabled
1: always enabled
2: only enabled when decelerating
1
1
×
FC.01
Initial voltage of
dynamic braking
220V: 340~380V 360V
380V: 660~760V 680V
1V
Depending
on model
o
FC.02
Hysteresis voltage of
dynamic braking
220V: 10~100V 5V
380V: 10~100V 10V
1V
Depending
on model
o
FC.03
Action ratio of
dynamic braking
10~100%
1%
100%
o
FC.04
Restart after power
failure
0: disabled
1: start at start frequency
2: start in speed tracking mode
1
0
×
FC.05
Restart delay after
power failure
0.0~60.0s
0.1s
5.0
×
FC.06
Auto reset times
0~100
the setting value of 100 means unlimited
times
1
0
×
FC.07
Auto reset interval
0.1~60.0s
0.1
3.0
×