![VTS Medical Systems VTS5000 Series Скачать руководство пользователя страница 184](http://html1.mh-extra.com/html/vts-medical-systems/vts5000-series/vts5000-series_operating-instructions-manual_1056181184.webp)
180
Fault code
Displayed code
Fault information
0000H
——
No fault
0001H
E-01
Overcurrent when accelerating
0002H
E-02
Overcurrent when decelerating
0003H
E-03
Overcurrent at constant speed
0004H
E-04
Overvoltage when accelerating
0005H
E-05
Overvoltage when decelerating
0006H
E-06
Overvoltage at constant speed
0007H
E-07
Bus undervoltage
0008H
E-08
Motor overload
0009H
E-09
Driver overload
000AH
E-10
Driver off load
000BH
E-11
Function module fault
000CH
E-12
Input phase loss
000DH
E-13
Output phase loss or current unbalance
000EH
E-14
Short circuit of output to earth
000FH
E-15
Heatsink overheat 1
0010H
E-16
Heatsink overheat 2
0011H
E-17
RS485 communication fault
0012H
E-18
Keypad communication fault
0013H
E-19
External device fault
0014H
E-20
Current detection fault
0015H
E-21
Motor tuning fault
0016H
E-22
EEPROM read-write fault
0017H
E-23
Parameters copy fault