140
0~2
0
0: start from the first stage
The driver restarts from the first stage of PLC after
interrupts, such as stop command, fault or poweroff.
1: continue from the stage where the driver stops
When the driver stops caused by stop command, fault
or poweroff, it can record the time that it has
undergone in the current stage. After restart, it will
run at the preset frequency of the stage for the
remaining time of the stage, as Fig. F9-4 shows.
Fig. F9-4 PLC Start Mode 1
2: start from the frequency where it stops (fault)
When the driver stops caused by stop command, fault
or poweroff, it can record both the time it has
undergone in the current stage and the very frequency
when the driver stops. After restart, it will pick up the
recorded frequency and run for the remaining time of
the stage. See Fig. F9-5.
Fig.F9-5 PLC Start Mode 2
Notice:
The difference between PLC start mode 1 and mode 2
is that in mode 2, the driver can record the operating
frequency when the driver stops and continue to
operate at the recorded frequency after restart.
F9.04
Limited times of continuous cycle
1~65535
1
F9.05
Unit of PLC operating time