4 Function Parameter Table and Description
4.0 Monitoring Parameter Group and Fault Record
D Group - Monitoring Parameter Group and Fault Record
Function
Code
Name
Set Range
Minimum
Unit
Factory
Default
Modification
d-00
Output Frequency
0.00~maximum output frequency
【
F0.15
】
0.01Hz
0.00
◆
d-01
Set Frequency
0.00~maximum output frequency
【
F0.15
】
0.01Hz
0.00
◆
d-02
Estimated Motor
Frequency
0.00~maximum output frequency
【
F0.15
】
Note: motor running frequency
converted from estimated motor speed
0.01Hz
0.00
◆
d-03
Main Set
Frequency
0.00~maximum output frequency
【
F0.15
】
0.01Hz
0.00
◆
d-04
Auxiliary Set
Frequency
0.00~maximum output frequency
【
F0.15
】
0.01Hz
0.00
◆
d-05
Output Current
0.0~6553.5A
0.1A
0.0
◆
d-06
Output Voltage
0~999V
1V
0
◆
d-07
Output Torque
-200.0~+200.0%
0.1%
0.0%
◆
d-08
Motor Revolving
Speed (RPM/min)
0~36000(RPM/min)
1
0
◆
d-09
Motor Power
Factor
0.00~1.00
0.01
0.00
◆
d-10
Run Linear Velocity
0.01~655.35(m/s)
0.01 m/s
0.00
◆