![VTS Medical Systems VTS5000 Series Скачать руководство пользователя страница 77](http://html1.mh-extra.com/html/vts-medical-systems/vts5000-series/vts5000-series_operating-instructions-manual_1056181077.webp)
73
FA.09
Current limiting in
constant speed
running
0: disabled
1: enabled
1
1
×
FA.10
Off load detection
time
0.1S~60.0S
0.1S
5.0
o
FA.11
Off load detection
level
0~100%*VFD rated current
0: off load detection is disabled
1%
0%
o
FA.12
Overload pre-alarm
level
G type: 20%~200%*VFD rated current
160%
P type: 20%~200%*VFD rated current
120%
1%
Depending
on model
o
FA.13
Overload pre-alarm
delay time
0.0~30.0s
0.1s
10.0
o
FA.14
Temperature
detection threshold
0.0
℃
~90.0
℃
0.1
℃
65.0
℃
×
FA.15
Phase loss
protection of input
and output
0: disabled
1: disabled for input, enabled for output
2: enabled for input, disabled for output
3: enabled
1
Depending
on model
×
FA.16
Delay time of input
phase loss
protection
0.0~30.0s
0.1S
1.0
o
FA.17
Detection
reference of output
phase loss
protection
0%~100%*VFD rated current
1%
50%
×
FA.18
Detection factor of
output current
1.00~10.00 1.00: imbalance detection is
disabled
—
1.00
×