63
value
F7.34
Time out
processing
0: stop timing, stop output
1: stop timing, resume output
2: cycle timing, stop output
3: cycle timing, resume output
1
3
×
F7.35
Timing start
condition
0: timing starts since power on
1: timing starts in operation status, and
stops in stop status
1
1
×
F7.36
Timing setting
0~65535S
1s
0
o
F7.37
Y1 turn off delay
time
0.0~100.0s
0.1s
0.0
×
F7.38
Y2 turn off delay
time
0.0~100.0s
0.1s
0.0
×
F7.39
R1 turn off delay
time
0.0~100.0s
0.1s
0.0
×
F7.40
R2 turn off delay
time
0.0~100.0s
0.1s
0.0
×
F8 Group – PID Control Parameters
F8.00
PID operation
input mode
0: auto
1: manually input via defined
multi-function terminal
1
0
×
F8.01
PID input channel
0: digital setting
1: AI1
2: AI2
3: pulse setting
4: RS485 communication
5 : given pressure(Mpa,Kg)
6 : given by panel potentiometer
1
0
o