52
physical quantity
setting
F6.09
AI2 input upper
limit
0.00V~10.00V
0.01V
10.00
o
F6.10
AI2 upper limit
corresponding
physical quantity
setting
-200.0%~200.0%
Note: range is relevant to F6.00
0.1%
100.0%
o
F6.11
AI2 input filtering
time
0.00S~10.00S
0.01S
0.05
o
F6.12
Error limit of
analog input
0.00V~10.00V
0.01V
0.10
o
F6.13
Threshold of zero
freq. operation
Zero freq. hysteresis~50.00Hz
0.01Hz
0.00
o
F6.14
zero freq.
hysteresis
0.00~zero freq. threshold value
0.01Hz
0.00
o
F6.15
External impulse
input
corresponding
physical quantity
0: speed command(output
freq.,-100.0%~100.0%)
1: torque command(output
torque,-200.0%~200.0%)
1
0
×
F6.16
External impulse
input lower limit
0.00~50.00KHz
0.01KH
z
0.00
o
F6.17
external impulse
lower limit
corresponding
physical quantity
set
-200.0%~200.0%
note: range is relevant to F6.15
0.1%
0.0%
o
F6.18
External impulse
0.00~50.00KHz
0.01KH
50.00
o