www.vtiinstruments.com
EX1629 Command Set
299
vtex1629_trig_init
F
UNCTION
P
ROTOTYPE
ViStatus vtex1629_trig_init (ViSession
vi
);
F
UNCTION
P
ARAMETERS
vi
= contains a session handle to the instrument. This handle is obtained by the function and remains valid until the
session is closed.
D
ATA
I
TEM
R
ESET
V
ALUE
Not applicable to this function.
D
ESCRIPTION
This function initiates the trigger system. Specifically, calling this function moves the trigger state machine from the
Idle layer into the Init layer.
E
XAMPLE
ViSession instrumentHandle;
ViStatus status;
…
status = vtex1629_trig_init(instrumentHandle);
Содержание EX1629
Страница 310: ...VTI Instruments Corp 310 EX1629 Command Set...
Страница 342: ...VTI Instruments Corp 342 EX1629 Onboard Memory...