Error Code Error Message
Meaning
FFBFFC0A42 VTEX1629_ERROR_CAL_UNSET_VALUES
Missing calibration data.
FFBFFC0A43 VTEX1629_ERROR_CAL_FILENAME_TOO_LONG
Calibration file name too long.
FFBFFC0A44 VTEX1629_ERROR_CAL_NOMINAL_CAL_NOT_PRESENT
Calibration file missing.
FFBFFC0A45 VTEX1629_ERROR_INVALID_CUTOFF_FREQ
Invalid filter cutoff frequency.
FFBFFC0A46 VTEX1629_ERROR_SHUNT_FP_VAL_UNEQUAL
Front panel resistor value is not equal for
blocks of 16 channels.
FFBFFC0A47 VTEX1629_ERROR_LXI_INPUT_CONFIG_CONFLICT
LXI input configuration conflicts with an
existing output.
FFBFFC0A48 VTEX1629_ERROR_LXI_OUTPUT_CONFIG_CONFLICT
LXI output configuration conflicts with an
existing input.
FFBFFC0A49 VTEX1629_ERROR_LXI_INPUT_MISCONFIGURATION
The specified LXI input line is not
configured as an input.
FFBFFC0A4A VTEX1629_ERROR_LXI_OUTPUT_MISCONFIGURATION
The specified LXI output line is not
configured as an output.
FFBFFC0A4B VTEX1629_ERROR_LXI_OUTPUT_CONFLICT
The specified LXI output conflicts with
another output.
FFBFFC0A4C VTEX1629_ERROR_INVALID_MODE_FOR_SOFT_TRIGGERARM
Software arm and trigger is only
available in trigger pattern mode.
FFBFFC0A4D VTEX1629_ERROR_PRETRIGGER_NOT_SUPPORTED_YET
Pre-trigger samples are not yet
supported.
FFBFFC0A4E VTEX1629_ERROR_NO_SERIAL_NUMBER
No serial number programmed on
device.
FFBFFC0A4F VTEX1629_ERROR_FIFO_STREAMING_ENABLED
Read FIFO not valid. Streaming interface
is enabled.
FFBFFC0A50 VTEX1629_ERROR_INSUFFICIENT_UPTIME_FOR_CAL
Insufficient instrument uptime to perform
calibration. Please see User's Manual for
more details.
FFBFFC0A51 VTEX1629_ERROR_CAL_SELF_CAL_NOT_PRESENT
Self-calibration file not present.
FFBFFC0A51 VTEX1629_ERROR_CAL_SELF_CAL_NOT_PRESENT
Self-calibration data is not present.
FFBFFC0A52 VTEX1629_ERROR_FPGA_TRIGINIT_NOT_IN_IDLE_STATE
Trigger state machine is not in the idle
state.
FFBFFC0A53 VTEX1629_ERROR_FPGA_TRIGINIT_IDLE_TO_ACQ_TIMEOUT
Time out in trigger system.
FFBFFC0A54 VTEX1629_ERROR_NO_MAC_ADDR
No MAC Address programmed on
device.
FFBFFC0A55 VTEX1629_ERROR_CAL_IN_PROGRESS
Some operations cannot be performed
while self-calibration is in progress.
FFBFFC0A56 VTEX1629_ERROR_CAL_BLOCKS_PRESENT
Calibration blocks detected.
FFBFFC0A57 VTEX1629_ERROR_XML_REQUIRE_TEDS
Required TEDS ID not available.
FFBFFC0A58 VTEX1629_ERROR_TRIGINIT_FPGA_ADC_INTR_OFF
A soft sync is required before trigger
initialization can be performed.
FFBFFC0A59 VTEX1629_ERROR_SHUNT_FPS_ENABLED_ON_MULTIPLE_CHANNELS
Within sixteen channel blocks
FFBFFC0A5A VTEX1629_ERROR_INVALID_TRIGGER_COUNT
Trigger/arm count must be greater than
zero.
FFBFFC0A5B VTEX1629_ERROR_SET_INT_SHUNT_VALUE
Internal shunt resistor is not user
defined.
FFBFFC0A5C VTEX1629_ERROR_INVALID_PULLUP_VALUE
Invalid pullup value.
FFBFFC0A5D VTEX1629_ERROR_INVALID_DIO_DIRECTION
Invalid DIO direction.
FFBFFC0A5E VTEX1629_ERROR_INVALID_URN_SIZE
Invalid MLAN URN size.
FFBFFC0A5F VTEX1629_ERROR_INVALID_USER_DATA
Invalid user data.
FFBFFC0A60 VTEX1629_ERROR_CONFIG_FILE_NOT_PRESENT
Specified configuration file not present.
FFBFFC0A61 VTEX1629_ERROR_INCONSISTENT_CONF_WT
Confidence weight is not consistent
across all channels.
FFBFFC0A62 VTEX1629_ERROR_INCONSISTENT_TRIGGER_TIMESTAMP
Trigger timestamp is not consistent
across all channels.
FFBFFC0A63 VTEX1629_ERROR_INCONSISTENT_SYNC_TIMESTAMP
Sync timestamp is not consistent across
all channels.
FFBFFC0A64 VTEX1629_ERROR_MLAN_BUFFER_OVERFLOW
MicroLAN buffer overflow.
FFBFFC0A65 VTEX1629_ERROR_MLAN_BUFFER_LEN_MISMATCH
MicroLAN buffer length mismatch.
FFBFFC0A66 VTEX1629_ERROR_UNSUPPORTED_TEDS_DEVICE
Unsupported TEDS device.