VTI Instruments Corp.
306
EX1629 Command Set
Error Code Error Message
Meaning
FFBFFC0A67 VTEX1629_ERROR_INCORRECT_TEDS_ID_LEN
Incorrect TEDS device ID length.
FFBFFC0A68 VTEX1629_ERROR_INCORRECT_TEDS_DATA_LEN
Incorrect TEDS data length.
FFBFFC0A69 VTEX1629_ERROR_TEDS_DATA_READBACK_FAILURE
TEDS device readback failure.
FFBFFC0A6A VTEX1629_ERROR_FIFO_OVERFLOW
Data FIFO overflowed.
FFBFFC0A6B VTEX1629_ERROR_EXTERNAL_ADC_MASTER_CLOCK_LOST
External ADC master clock was lost.
FFBFFC0A6C VTEX1629_ERROR_INVALID_CONF_FILTER_WT
Invalid confidence filter weight.
FFBFFC0A6D VTEX1629_ERROR_IIR_NOT_SUPPORTED_FOR_CURR_FS
IIR filter is not supported for the current
sample frequency.
FFBFFC0A6E VTEX1629_ERROR_CAL_FACTORY_MODE_REQUIRED
The system must be in factory mode to
perform this action.
FFBFFC0A6F VTEX1629_ERROR_FS_NOT_SUPPORTED_WHEN_CONF_EN
This sample frequency is not supported
when confidence sources are enabled.
FFBFFC0A70 VTEX1629_ERROR_CONF_OPS_NOT_SUPPORTED_FOR_CURR_FS
Confidence operations are not supported
at this sample frequency.
FFBFFC0A71 VTEX1629_ERROR_INVALID_VI_SESSION
Invalid or null session to the instrument
passed as parameter to function.
FFBFFC0A72 VTEX1629_ERROR_RUNTIME_INVALID_PARAMETER
Invalid or null parameter passed to
function.
FFBFFC0A73 VTEX1629_ERROR_ILLEGAL_TRIGGER_SAMPLE_COUNT_SPECIFIED
Illegal trigger sample count.
FFBFFC0A74 VTEX1629_ERROR_ILLEGAL_PRETRIGGER_SAMPLE_COUNT_SPECIFIED
Illegal pretrigger sample count.
FFBFFC0A75 VTEX1629_ERROR_INVALID_ARM_SOURCE
Invalid arm source parameter.
FFBFFC0A76 VTEX1629_ERROR_INVALID_ARM_COUNT
Invalid arm count parameter.
FFBFFC0A77 VTEX1629_ERROR_INVALID_EXCITATION_SRC
Invalid excitation source. Use
VTEX1629_EXCITE_SRC_LOCAL or
VTEX1629_EXCITE_SRC_REMOTE.
FFBFFC0A78 VTEX1629_ERROR_INVALID_SYNCH_SOURCE
Invalid synch source parameter.
FFBFFC0A79 VTEX1629_ERROR_INVALID_TRIGGER_DELAY
Invalid trigger delay parameter.
FFBFFC0A7A VTEX1629_ERROR_INVALID_TIMER_PERIOD
Invalid timer period parameter.
FFBFFC0A7B VTEX1629_ERROR_INVALID_MLAN_DATA_LEN
Invalid MLAN data length parameter.
FFBFFC0A7C VTEX1629_ERROR_CALCULATING_SETTLING_TIME
Error while calculating settling time.
FFBFFC0A7D VTEX1629_ERROR_INVALID_ARM_DELAY
Invalid arm delay parameter.
FFBFFC0A7E VTEX1629_ERROR_RESERVED_CODE_1220
Reserved Error Code 0x1220.
FFBFFC0A7F VTEX1629_ERROR_INCONSISTENT_SAMP_CLK_SRC
Clock source is not consistent across all
channels and digital backend.
FFBFFC0A80 VTEX1629_ERROR_HD_INVALID_STATE_TRANSITION
Improper sequence of hard disk
commands.
FFBFFC0A81 VTEX1629_ERROR_HD_MOUNT_FAIL
Error mounting hard disk.
FFBFFC0A82 VTEX1629_ERROR_HD_UNMOUNT_FAIL
Error unmounting hard disk.
FFBFFC0A83 VTEX1629_ERROR_HD_FILE_EXISTS
Hard disk file exists.
FFBFFC0A84 VTEX1629_ERROR_HD_NO_DATA_FILE
No data file.
FFBFFC0A85 VTEX1629_ERROR_HD_NO_INDEX_FILE
No index file.
FFBFFC0A86 VTEX1629_ERROR_HD_FILE_OPEN_FAIL
Failure when attempting to open file.
FFBFFC0A87 VTEX1629_ERROR_HD_NOT_SUPPORTED
Hard disk not supported.
FFBFFC0A88 VTEX1629_ERROR_HD_HANG
Hard disk hang.
FFBFFC0A89 VTEX1629_ERROR_NET_HANG
Network hang.
FFBFFC0A8A VTEX1629_ERROR_INVALID_EUCONV_EXCITATION_VOLT_SRC
Illegal mode parameter.
FFBFFC0A8B VTEX1629_ERROR_ARG_OUT_OF_RANGE
Argument out of range.
FFBFFC0A8C VTEX1629_ERROR_INVALID_FS_FOR_THIS_SCANLIST
Maximum sample rate exceeded for
current scanlist. Maximum is 12.5 kSa/s
on 16 channels constrained to a bank of
1-15.
FFBFFC0A8D VTEX1629_ERROR_INVALID_SCANLIST_FOR_THIS_FS
Maximum channels in scanlist exceeded
for current sample rate. Maximum is 16
channels constrained to a bank of 1-15.
FFBFFC0A8E VTEX1629_ERROR_DIO_NO_INPUT_BANK_CONFIGURED
Digital error. No input bank configured.
FFBFFC0A8F VTEX1629_ERROR_DIO_NO_OUTPUT_BANK_CONFIGURED
Digital error. No output bank configured.
FFBFFC0A90 VTEX1629_ERROR_DIO_CONFLICT_OUTPUT_IN_USE
Digital IO conflict because output is in
use.
Содержание EX1629
Страница 310: ...VTI Instruments Corp 310 EX1629 Command Set...
Страница 342: ...VTI Instruments Corp 342 EX1629 Onboard Memory...