ECU converter JetCat Version: 1.0
Page 9/38
2.1.2.4
Turbinestatus / OFF-Condition – numerial Values
The turbines status messages are also displayed numerical values. The assignment is given in
the following table.
These status values can be used in Jeti radios, e.g. in logical links, or in LUA-supported radios
for LUA scripts.
Status/OC Description
0
OFF
1
Slow Down
2
AutoOff
3
WAIT for RPM (Stby/Start)
4
PreHeat1 (only for direct Kerosene startup mode)
5
PreHeat2 (only for direct Kerosene startup mode)
6
Ignite
7
Accleleration delay
8
MainFStrt (only for direct Kerosene startup mode)
9
Keros.FullOn (only for direct Kerosene startup mode)
10
Accelerate
11
Stabilise
12
Learn LO
13
Run (reg.)
14
SpeedReg (Speed Ctrl)
15
Two-Shaft-Regulate (only for turbines with secondary shaft)
-1
Shut down via RC
-2
Auto Off
-3
Manual Off (via GSU)
-4
Acceleration time out
-5
Acceleration too slow
-6
Over RPM
-7
Low Rpm Off
-8
Low Battery
-9
Overtemperature
-10
Low temperature Off
-11
Hi Temp Off
-12
Glow Plug defective
-13
Watch Dog Timer
-14
Fail Safe Off
-15
Ignition timeout
-16
Power fail (Battery fail)
-17
Temp Sensor fail (only during startup)
-18
Fuel fail
-19
Prop fail (only two shaft engines)
-20
2nd engine fail
-21
2nd engine differential to high
-22
2nd engine no communication
-23
No oil (only on engines with separate oil reservoir)
-24
Over current
-25
No fuel pump connected/found
-26
Wrong fuelpump connected
-27
Fuelpump communication error
-28
Out of fuel shut down (only on engines with fuel sensor, like RXi types)
-29
Low Rpm shutdown, possibly due to Pump failure
-30
Low Rpm shutdown, possibly due to frontboard failure
-31
Clutch fail (starter motor clutch is not decoupling)
-32
ECU reboot due to re-matching of new engine connected
-40
(-
4
…-32) once for 2 seconds, e.g. for sum alarm