ECU converter JetCat Version: 1.0
Page 31/38
2.6.1
Turbinestatus / OFF-Condition – numerial „Temperature“-Values
The turbines status messages are also displayed numerical values. The assignment is given in
the following table.
Tmp2
Description
0
OFF
1
Slow Down
2
AutoOff
3
WAIT for RPM (Stby/Start)
4
PreHeat1 (only for direct Kerosene startup mode)
5
PreHeat2 (only for direct Kerosene startup mode)
6
Ignite
7
Accleleration delay
8
MainFStrt (only for direct Kerosene startup mode)
9
Keros.FullOn (only for direct Kerosene startup mode)
10
Accelerate
11
Stabilise
12
Learn LO
13
Run (reg.)
14
SpeedReg (Speed Ctrl)
15
Two-Shaft-Regulate (only for turbines with secondary shaft)
-1
Shut down via RC
-2
Auto Off
-3
Manual Off (via GSU)
-4
Acceleration time out
-5
Acceleration too slow
-6
Over RPM
-7
Low Rpm Off
-8
Low Battery
-9
Overtemperature
-10
Low temperature Off
-11
Hi Temp Off
-12
Glow Plug defective
-13
Watch Dog Timer
-14
Fail Safe Off
-15
Ignition timeout
-16
Power fail (Battery fail)
-17
Temp Sensor fail (only during startup)
-18
Fuel fail
-19
Prop fail (only two shaft engines)
-20
2nd engine fail
-21
2nd engine differential to high
-22
2nd engine no communication
-23
No oil (only on engines with separate oil reservoir)
-24
Over current
-25
No fuel pump connected/found
-26
Wrong fuelpump connected
-27
Fuelpump communication error
-28
Out of fuel shut down (only on engines with fuel sensor, like RXi types)
-29
Low Rpm shutdown, possibly due to Pump failure
-30
Low Rpm shutdown, possibly due to frontboard failure
-31
Clutch fail (starter motor clutch is not decoupling)
-32
ECU reboot due to re-matching of new engine connected
-40
(-
4
…-32) once for 2 seconds, e.g. for sum alarm