ECU converter JetCat Version: 1.0
Page 23/38
2.4.1
Turbinestatus – numerical "Current"-Values
The turbines status messages are displayed as numerical "Current" values. The assignment is
given in the following table:
CUR-F1678
CURRENT
Description
0.0 A
OFF
1.0 A
Slow Down
2.0 A
AutoOff
3.0 A
WAIT for RPM (Stby/Start)
4.0 A
PreHeat1 (only for direct Kerosene startup mode)
5.0 A
PreHeat2 (only for direct Kerosene startup mode)
6.0 A
Ignite
7.0 A
Accleleration delay
8.0 A
MainFStrt (only for direct Kerosene startup mode)
9.0 A
Keros.FullOn (only for direct Kerosene startup mode)
10.0 A
Accelerate
11.0 A
Stabilise
12.0 A
Learn LO
13.0 A
Run (reg.)
14.0 A
SpeedReg (Speed Ctrl)
15.0 A
Two-Shaft-Regulate (only for turbines with secondary shaft)
- 1.0 A
all turbine shutdowns, except:
- RC-Off
- Auto-Off
- Manual-Off
- 2.0 A
like – 1.0A, but only once for 2 seconds, e.g. for sum alarm
If in the transmitter an alarm thresold for the current of e.g. less than MINUS 1.0A is set, all
turbine shutdowns except for "RC-Off", "Auto-Off" and "Manual -Off" are signaled as a current
alarm for a period of 2 seconds.
2.4.2
Telemetry Box
On the Telemetry Box, the data of the
VSpeak ECU converter can also be
displayed (in the picture e.g. fuel
consumption
1560ml)
and
alarms
corresponding section 2.4.4 are generated:
STATUS, BATT, FUEL, RPM and
RPM2
With the latest software (V1.003 - as of
May 2015) the sensors
SBS-01V and
SBS-01T
are not supported yet.