ECU converter JetCat Version: 1.0
Page 30/38
2.6
FrSKY S.Port
(tested with Taranis X9D with FW: opentx-taranis-plus VERS: 2.1.8)
The telemetry data from the ECU converter are only transmitted to the sender via the FrSky
SmartPort. A parameterization of the evoJet ECU is not possible with this system.
After the sensor settings of the VSpeak ECU converter have been read in the "TELEMETRY"
model settings with "Start Sensorsuche", the PREZISION of "fuel” should be changed from
0.00 to 0.- - ml, A3 (BATT) from 0.00 to 0.0 V and for ASpd (Airspeed) from 0.0 to 0.- - kmh
The second "fuel" value with the unit % is renamed "Thro" (exactly this notation, otherwise
the LUA script does not work correctly).
With the following arrangement of the values in Telm-Bild 1
… the telemetry data are represented as follows:
FrSKY Telm-Bild 1
JetCat
Tmp2
ECU-Status and OFF Cond. as Temperature
(s. section 2.6.1)
A4
PUMP in V
Tmp1
EGT in °C
RPM
Turbine or 2nd Shaft
(s. section 2.6.3)
Fuel
FUEL (remaining fuel) in ml
A3
BATT in V
Thro
THROTTLE in %
ASpd
OFF / kts / kmh
(s. section 2.6.3)