ECU converter JetCat Version: 1.0
Page 6/38
Globale Parameters
If ECU converter, GSU and a (2-3 cell LiPo / LiFe) battery are connected to the Programming
adapter, the "Limits" button is used to set global parameters which are the same for all remote
control systems:
OFF, 10 . . . 2500 ml
Set: 800 ml
5.0 . . . 12.0 V
Set: 5.0 V
OFF, 20.000 . . . 99.900 rpm
Set: OFF
100 . . . 990°C
Set: 800°C
OFF, 1.000 . . . 99.900 rpm
Set: OFF
OFF, 10 . . . 150 kmh
Set: OFF
OFF, 80 . . . 990 kmh
Set: OFF
The parameters are largely self-explanatory, lower values as "Low" thresholds and exceeding
of the "High" thresholds trigger alarms, with "OFF" the respective alarm is deactivated.
The "Low ..." alarms are activated after at first exceeding the "Low ..." alarm threshold. The
low RPM (and RPM2) alarm ends at PUMP = 0.00V, which means that the speed alarm is
suitable for signaling a "turbine flameout".
"Set" are the values set at delivery.
Low Battery
: 5 . 0 V
Low RPM
: OFF rpm
Low RPM 2Shaft
: OFF rpm
H i gh EGT
: 800 C
Low A i rspeed
: OFF kmh
H i gh A i rspeed
: OFF kmh
Low Fue l
: 800 m l