SD500 Spindle Servo Drive Manual
55
(0x071B)
speed tracking
Set stop time delay of speed tracking.
(0.0~60.0s)
F07.28
(0x071C)
Speed tracking
current
V/F SVC FVC PMVF PMSVC PMFVC
Set speed tracking current.
120.0%
(0.0~400.0%)
STOP
Table 4-29
Group F07.3x: Jogging
Parameter code
(Address)
Designation
Content
Default
(Setting range)
Adjustable
properties
F07.30
(0x071E)
Jogging frequency
setting
V/F SVC FVC PMVF PMSVC PMFVC
Set jogging running frequency.
5.00Hz
(0.00~
Max.
frequency)
RUN
F07.31
(0x071F)
Jogging acceleration
time
V/F SVC FVC PMVF PMSVC PMFVC
Set jogging acceleration time.
10.0s
(0.0~650.0s)
RUN
F07.32
(0x0720)
Jogging deceleration
time
V/F SVC FVC PMVF PMSVC PMFVC
Set jogging deceleration time.
10.0s
(0.0~650.0s)
RUN
F07.33
(0x0721)
Jogging S-curve
selection
V/F SVC FVC PMVF PMSVC PMFVC
Set jogging S-curve selection.
0: invalid
;
1: valid
0
(0~1)
RUN
F07.34
(0x0722)
Jogging stop mode
selection
V/F SVC FVC PMVF PMSVC PMFVC
Set the jogging stop mode
0: set mode via F7.10; 1: deceleration stop only
0
(0~1)
STOP
Table 4-30
Group F07.4x: Start/Stop frequency holding and hopping frequency
Parameter code
(Address)
Designation
Content
Default
(Setting range)
Adjustable
properties
F07.40
(0x0728)
Holding frequency at
start-up
V/F SVC FVC PMVF PMSVC PMFVC
Holding frequency at start-up is larger than the starting
frequency and smaller than the upper frequency via number
setting
0.50Hz
(0.00~
Upper limit
frequency via
number setting)
STOP
F07.41
(0x0729)
Holding frequency
time at start-up
V/F SVC FVC PMVF PMSVC PMFVC
The setting value should be larger than the starting
frequency, and if it is not, it starts with the starting
frequency.
0.0s
(0.0~60.0s)
STOP
F07.42
(0x072A)
Holding frequency
during shutdown
V/F SVC FVC PMVF PMSVC PMFVC
Set the holding frequency during shutdown.
0.50Hz
(0.00~ Upper limit
STOP