SD500 Spindle Servo Drive Manual
42
terminal X5 from the invalid state to the valid state.
F05.19
(0x0513)
X5 invalidity
detection delay
V/F SVC FVC PMVF PMSVC PMFVC
The delay time corresponding to the transition of output
terminal X5 from the valid state to the invalid state.
0.010
(0.000~6.000s)
RUN
Table 4-23
Group F05.2x: Digital input terminal function selection
Parameter code
(Address)
Designation
Content
Default
(Setting range)
Adjustable
properties
F05.20
(0x0514)
Terminal control
running mode
V/F SVC FVC PMVF PMSVC PMFVC
0: two-wire mode 1; 1: two-wire mode 2
2: three-wire mode 1; 3: three-wire mode 2
Note: see Appendix II for the terminal wiring methods.
0
(0~3)
STOP
F05.22
(0x0516)
X1~X4 terminal
characteristics
selection
V/F SVC FVC PMVF PMSVC PMFVC
0: valid when closed
;
1: valid when open
Ones-bit: X1 terminal
Tens-bit: X2 terminal
Hundreds-bit: X3 terminal
Thousands-bit: X4 terminal
0000
(0000~1111)
RUN
F05.23
(0x0517)
X5~X7 terminal
characteristics
selection
V/F SVC FVC PMVF PMSVC PMFVC
0: valid when closed
;
1: valid when open
Ones-bit: X5 terminal
Tens-bit: X6 terminal
Hundreds-bit: X7 terminal
0000
(0000~0111)
RUN
F05.25
(0x0519)
Terminal UP/DW
control selection
V/F SVC FVC PMVF PMSVC PMFVC
0:
power-down frequency storage
1: no power-down frequency storage
2:
frequency adjustable during running, records all cleared at
stop
0
(0~2)
STOP
F05.26
(0x051A)
Terminal UP/DW
for the increase
/decrease rate of
frequency
V/F SVC FVC PMVF PMSVC PMFVC
Set terminal UP/DW to control the increase or decrease rate
of frequency.
0.50Hz/s
(0.01~50.00Hz/s)
RUN
F05.27
Terminal controlling
V/F SVC FVC PMVF PMSVC PMFVC
1.00s