SD500 Spindle Servo Drive Manual
45
F05.59
(0x053B)
AI2 filtering time
V/F SVC FVC PMVF PMSVC PMFVC
Set the filter for the analog signal to eliminate interfering
signals.
0.010s
(0.000~6.000s)
RUN
Table 4-27
Group F05.6x:AI curve 1 processing
Parameter code
(Address)
Designation
Content
Default
(Setting range)
Adjustable
properties
F05.60
(0x053C)
Curve 1 lower limit
V/F SVC FVC PMVF PMSVC PMFVC
Set the lower limit of curve 1.
0.0%
(0.0~100.0%)
RUN
F05.61
(0x053D)
Percent of curve 1
lower limit
V/F SVC FVC PMVF PMSVC PMFVC
Set percent of curve 1 lower limit.
0.0%
(0.0~100.0%)
RUN
F05.62
(0x053E)
Curve 1 inflection
point 1 input voltage
V/F SVC FVC PMVF PMSVC PMFVC
Set curve 1 inflection point 1 input voltage.
30.0%
(0.0~100.0%)
RUN
F05.63
(0x053F)
Percent of curve 1
inflection point 1
input voltage
V/F SVC FVC PMVF PMSVC PMFVC
Set percent of curve 1 inflection point 1 input voltage.
30.00%
(0.0~100.0%)
RUN
F05.64
(0x0540)
Curve 1 inflection
point 2 input voltage
V/F SVC FVC PMVF PMSVC PMFVC
Set curve 1 inflection point 2 input voltage.
60.0%
(0.0~100.0%)
RUN
F05.65
(0x0541)
Percent of curve 1
inflection point 2
input voltage
V/F SVC FVC PMVF PMSVC PMFVC
Set the percent of curve 1 inflection point 2 input voltage.
70.00%
(0.0~100.0%)
RUN
F05.66
(0x0542)
Curve 1 upper limit
V/F SVC FVC PMVF PMSVC PMFVC
Set the upper limit of curve 1.
100.00%
(0.0~100.0%)
RUN
F05.67
(0x0543)
Percent of curve 1
upper limit
V/F SVC FVC PMVF PMSVC PMFVC
Percent of curve 1 upper limit
100.0%
(0.0~100.0%)
RUN
Table 4-28
Group F05.7x:AI curve 2 processing
Parameter code
(Address)
Designation
Content
Default
(Setting range)
Adjustable
properties
F05.70
(0x0546)
Curve 2 lower limit
V/F SVC FVC PMVF PMSVC PMFVC
Set the lower limit value of curve 2.
0.0%
(0.0~100.0%)
RUN
F05.71
(0x0547)
Percent of curve 2
lower limit
V/F SVC FVC PMVF PMSVC PMFVC
Set percent of curve 2 lower limit.
0.0%
(0.0~100.0%)
RUN