SD500 Spindle Servo Drive Manual
39
F03.47
(0x032F)
Torque filter time
V/F SVC FVC PMVF PMSVC PMFVC
Set frequency amplitude limited by torque at low speed.
0.100s
(0.000~6.000s)
RUN
F03.52
(0x0334)
Upper limit of
output torque
V/F SVC FVC PMVF PMSVC PMFVC
Set the upper limit of output torque.
150.0%
(0.0~200.0%)
RUN
F03.53
(0x0335)
Lower limit of
output torque
V/F SVC FVC PMVF PMSVC PMFVC
Set the lower limit of output torque.
0.0%
(0.0~200.0%)
RUN
F03.54
(0x0336)
Torque controlling
forward speed limit
selection
V/F SVC FVC PMVF PMSVC PMFVC
0:Set via function code F03.56;
1: Reserved;
2:AI1×F03.56;
3:AI2×F03.56
;
4: Reserved;
5: PUL×F03.56;
6: Given value via RS485 communication × F03.56;
7:Reserved
;
0
(0~7)
RUN
F03.55
(0x0337)
Torque controlling
reverse speed limit
selection
V/F SVC FVC PMVF PMSVC PMFVC
0: Set via function code F03.57;
1: Reserved;
2:AI1×F03.57
;
3:AI2×F03.57
;
4: Reserved
;
5:PUL×F03.57
;
6: Given value via RS485 communication×F03.57
7: Reserved
;
0
(0~7)
RUN
F03.56
(0x0338)
Torque controlling
max. speed limit for
forward rotation
V/F SVC FVC PMVF PMSVC PMFVC
Set the maximum speed limit for torque controlling forward
rotation.
100.0%
(0.0~100.0%)
RUN
F03.57
(0x0339)
Torque controlling
max. speed limit for
reverse rotation
V/F SVC FVC PMVF PMSVC PMFVC
Set the maximum speed limit for torque controlling reverse
rotation.
100.0%
(0.0~100.0%)
RUN
Table 4-19
Group F03.7x: Position compensation
Parameter code
Designation
Content
Default
Adjustable