SD500 Spindle Servo Drive Manual
35
F02.72
(0x0249)
SIN COS min.
threshold
V/F SVC FVC PMVF PMSVC PMFVC
The minimum threshold for the sum of squares of SIN COS
signal, report the E.PG13 fault below the threshold
2000
(1 ~10000)
RUN
F02.73
(0x024A)
Sine/cosine crossover
output cable No.
V/F SVC FVC PMVF PMSVC PMFVC
The number of encoder cables for crossover output.
1024
(0 ~10000)
STOP
Table 4-14
4.6 Group F03: Vector Control
Group F03.0x: Speed loop
Parameter code
(Address)
Designation
Content
Default
(Setting range)
Adjustable
properties
F03.00
(0x0300)
ASR speed rigidity
grade
V/F SVC FVC PMVF PMSVC PMFVC
Rigidity level setting, the higher the level, the better the speed
rigidity.
32
(0~64)
RUN
F03.01
(0x0301)
ASR speed rigidity
mode
V/F SVC FVC PMVF PMSVC PMFVC
ASR speed rigidity mode.
0x0000
(0x0000~0xffff)
RUN
F03.02
(0x0302)
ASR (speed loop)
proportional gain1
V/F SVC FVC PMVF PMSVC PMFVC
Set the ASR (speed loop) proportional gain 1.
20.00
(0.01~100.00)
RUN
F03.03
(0x0303)
ASR (speed loop )
integral time 1
V/F SVC FVC PMVF PMSVC PMFVC
Set the ASR (speed loop) integral time 1.
0.100s
(0.000~6.000s)
RUN
F03.04
(0x0304)
ASR filter time1
V/F SVC FVC PMVF PMSVC PMFVC
Set the ASR filter time 1.
0.0ms
(0.0~100.0ms)
RUN
F03.05
(0x0305)
ASR switching
frequency1
V/F SVC FVC PMVF PMSVC PMFVC
Set the ASR switching frequency 1.
10.00Hz
(0~
Max.
frequency)
RUN
F03.06
(0x0306)
ASR (speed loop)
proportional gain2
V/F SVC FVC PMVF PMSVC PMFVC
Set the ASR (speed loop) proportional gain 2.
10.00
(0.01~100.00)
RUN
F03.07
(0x0307)
ASR (speed loop)
integral time 2
V/F SVC FVC PMVF PMSVC PMFVC
Set the ASR (speed loop) integral time 2.
0.050s
(0.000~6.000s)
RUN
F03.08
(0x0308)
ASR filter time 2
V/F SVC FVC PMVF PMSVC PMFVC
Set the ASR filter time 2.
0.0ms
(0.0~100.0ms)
RUN
F03.09
(0x0309)
ASR switching
frequency 2
V/F SVC FVC PMVF PMSVC PMFVC
Set the ASR switching frequency 2.
5.00Hz
(0~
最大频率
)
RUN
Table 4-15
Group F03.1x: Current loop and torque limit